Among the new emerging cancer therapies, Microbeam Radiation Therapy (MRT) is currently showing very promising results in terms of limiting or decreasing tumor growth while keeping the damage to healthy tissue to a minimum. The MRT is able to deliver unprecedented dose rates of up to 20 kGy/s, posing important questions in terms of treatment planning and patient safety during treatment. For this reason, a beam monitoring system must be built, in which a detector acquires the microbeam array profile in real-time. In case of anomalies detection, the detector signals the beam-line to close the shutter as an emergency safety measure. Many sensors technologies for beam monitoring are currently being considered and silicon strip detectors seem to be very promising candidates. In this study the characterisation in full MRT conditions of a novel silicon strip detector is reported explaining strengths and weaknesses of the devices. Modifications to the sensor layout are also suggested in this study.

Povoli, M., Alagoz, E., Bravin, A., Cornelius, I., Bräuer-Krisch, E., Fournier, P., et al. (2016). Functional characterisation of novel silicon beam monitors for the micro-beam radiation therapy. In 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015 (pp.1-4). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2015.7581894].

Functional characterisation of novel silicon beam monitors for the micro-beam radiation therapy

Bravin A;
2016

Abstract

Among the new emerging cancer therapies, Microbeam Radiation Therapy (MRT) is currently showing very promising results in terms of limiting or decreasing tumor growth while keeping the damage to healthy tissue to a minimum. The MRT is able to deliver unprecedented dose rates of up to 20 kGy/s, posing important questions in terms of treatment planning and patient safety during treatment. For this reason, a beam monitoring system must be built, in which a detector acquires the microbeam array profile in real-time. In case of anomalies detection, the detector signals the beam-line to close the shutter as an emergency safety measure. Many sensors technologies for beam monitoring are currently being considered and silicon strip detectors seem to be very promising candidates. In this study the characterisation in full MRT conditions of a novel silicon strip detector is reported explaining strengths and weaknesses of the devices. Modifications to the sensor layout are also suggested in this study.
paper
Medical imaging; Patient treatment; Silicon; Silicon detectors; Silicon sensors
English
IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015 - 31 October 2015 through 7 November 2015
2015
2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015
9781467398626
2016
1
4
7581894
none
Povoli, M., Alagoz, E., Bravin, A., Cornelius, I., Bräuer-Krisch, E., Fournier, P., et al. (2016). Functional characterisation of novel silicon beam monitors for the micro-beam radiation therapy. In 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015 (pp.1-4). Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2015.7581894].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/416620
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
Social impact