This study assesses the accuracy and technical predictability of a computer-guided procedure for harvesting bone from the external oblique ridge using a patient-specific cutting guide. Twenty-two patients needing bone augmentation for implant placement were subjected to mandibular osteotomy employing a case-specific stereolithographic surgical guide generated through computer aided design. Differences between planned and real cut planes were measured comparing pre- and post-operative Cone Beam Computed Tomography images of the donor site according to six validated angular and displacement indexes. Accuracy and technical predictability were assessed for 119 osteotomy planes over the study population. Three different guide fitting approaches were compared. An average root-mean-square discrepancy of 0.52 (0.30–0.97) mm was detected. The accuracy of apical and medial planes was higher than the mesial and distal planes due to occasional antero-posterior guide shift. Fitting the guide with an extra reference point on the closest tooth performed better than using only the bone surface, with two indexes significantly lower and less disperse. The study showed that the surgical plan was actualized with a 1 mm safety margin, allowing effective nerve preservation and reducing technical variability. When possible, surgical guide design should allow fitting on the closest tooth based on both radiological and/or intra-oral scan data.

De Stavola, L., Cristoforetti, A., Fincato, A., Nollo, G., Ghensi, P., Cantarutti, A., et al. (2022). Accuracy and Technical Predictability of Computer Guided Bone Harvesting from the Mandible: A Cone-Beam CT Analysis in 22 Consecutive Patients. JOURNAL OF FUNCTIONAL BIOMATERIALS, 13(4) [10.3390/jfb13040292].

Accuracy and Technical Predictability of Computer Guided Bone Harvesting from the Mandible: A Cone-Beam CT Analysis in 22 Consecutive Patients

Cantarutti A.;
2022

Abstract

This study assesses the accuracy and technical predictability of a computer-guided procedure for harvesting bone from the external oblique ridge using a patient-specific cutting guide. Twenty-two patients needing bone augmentation for implant placement were subjected to mandibular osteotomy employing a case-specific stereolithographic surgical guide generated through computer aided design. Differences between planned and real cut planes were measured comparing pre- and post-operative Cone Beam Computed Tomography images of the donor site according to six validated angular and displacement indexes. Accuracy and technical predictability were assessed for 119 osteotomy planes over the study population. Three different guide fitting approaches were compared. An average root-mean-square discrepancy of 0.52 (0.30–0.97) mm was detected. The accuracy of apical and medial planes was higher than the mesial and distal planes due to occasional antero-posterior guide shift. Fitting the guide with an extra reference point on the closest tooth performed better than using only the bone surface, with two indexes significantly lower and less disperse. The study showed that the surgical plan was actualized with a 1 mm safety margin, allowing effective nerve preservation and reducing technical variability. When possible, surgical guide design should allow fitting on the closest tooth based on both radiological and/or intra-oral scan data.
Articolo in rivista - Articolo scientifico
accuracy; bone harvesting; computer assisted surgery; cone beam computed tomography; predictability;
English
10-dic-2022
2022
13
4
292
none
De Stavola, L., Cristoforetti, A., Fincato, A., Nollo, G., Ghensi, P., Cantarutti, A., et al. (2022). Accuracy and Technical Predictability of Computer Guided Bone Harvesting from the Mandible: A Cone-Beam CT Analysis in 22 Consecutive Patients. JOURNAL OF FUNCTIONAL BIOMATERIALS, 13(4) [10.3390/jfb13040292].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/410295
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact