Background: Postmastectomy radiotherapy (PMRT) with TomoHelical™ (TH) or TomoDirect™ (TD) allows a uniform target coverage. In this study, we compare treatment plans using TD and TH in the setting of hypofractionated PMRT and immediate breast reconstruction. Material and methods: The TD-treatment plans of breast cancer patients treated between May 2016 and August 2019 were retrospectively selected. All the TD plans were re-planned on TH with the same prescription dose (40.05 Gy/15 fractions) and according to our dose/volume constraints. Data about the 2 treatment plans were compared with a focus on PTV coverage and all the organs at risk (OARs) constraints. Results: Fifty patients for a total number of 100 treatment plans (50 with TD and 50 re-planned with TH) were analyzed. All the median value in the TD PTV CHEST WALL plans fulfilled the predefined planning objectives, even though TH emerged as best for target coverage with statistically significant difference for V90%. TD provided the lowest V95% for the PTV SVC, but the median value was near to the recommended value of 90% (89.8 % vs 98.6% for TD and TH, respectively). Overall, TD reached the best OARs sparing. The main statistically significant differences with TH were for contralateral breast, ipsilateral and contralateral lung. All the other dose values for TH were higher than TD, but they fulfilled the recommended/acceptable predefined planning objectives. Conclusions: In the setting of PMRT, TD compared to TH reached an acceptable target volume coverage, with an optimal sparing of OARs.

Dicuonzo, S., Patti, F., Luraschi, R., Frassoni, S., Rojas, D., Zaffaroni, M., et al. (2021). Comparing TomoHelical and TomoDirect in postmastectomy hypofractionated radiotherapy after immediate breast reconstruction. PHYSICA MEDICA, 90, 66-72 [10.1016/j.ejmp.2021.09.007].

Comparing TomoHelical and TomoDirect in postmastectomy hypofractionated radiotherapy after immediate breast reconstruction

Frassoni S.;Bagnardi V.;
2021

Abstract

Background: Postmastectomy radiotherapy (PMRT) with TomoHelical™ (TH) or TomoDirect™ (TD) allows a uniform target coverage. In this study, we compare treatment plans using TD and TH in the setting of hypofractionated PMRT and immediate breast reconstruction. Material and methods: The TD-treatment plans of breast cancer patients treated between May 2016 and August 2019 were retrospectively selected. All the TD plans were re-planned on TH with the same prescription dose (40.05 Gy/15 fractions) and according to our dose/volume constraints. Data about the 2 treatment plans were compared with a focus on PTV coverage and all the organs at risk (OARs) constraints. Results: Fifty patients for a total number of 100 treatment plans (50 with TD and 50 re-planned with TH) were analyzed. All the median value in the TD PTV CHEST WALL plans fulfilled the predefined planning objectives, even though TH emerged as best for target coverage with statistically significant difference for V90%. TD provided the lowest V95% for the PTV SVC, but the median value was near to the recommended value of 90% (89.8 % vs 98.6% for TD and TH, respectively). Overall, TD reached the best OARs sparing. The main statistically significant differences with TH were for contralateral breast, ipsilateral and contralateral lung. All the other dose values for TH were higher than TD, but they fulfilled the recommended/acceptable predefined planning objectives. Conclusions: In the setting of PMRT, TD compared to TH reached an acceptable target volume coverage, with an optimal sparing of OARs.
Articolo in rivista - Articolo scientifico
Breast cancer; Breast reconstruction; Postmastectomy hypofractionated radiotherapy; Radiotherapy; TomoDirect; TomoHelical;
English
2021
90
66
72
none
Dicuonzo, S., Patti, F., Luraschi, R., Frassoni, S., Rojas, D., Zaffaroni, M., et al. (2021). Comparing TomoHelical and TomoDirect in postmastectomy hypofractionated radiotherapy after immediate breast reconstruction. PHYSICA MEDICA, 90, 66-72 [10.1016/j.ejmp.2021.09.007].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/398235
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
Social impact