The performance of a single crystal diamond (4.7x4.7x0.5mm3 active volume) detector was tested in the ISIS pulsed neutron beam using biparametric (time of flight and pulse height) data acquisition. Three characteristic regions in the biparametric spectra are observed: i) low pulse height events with very short time of flight induced by γ-rays; ii) low pulse height events at longer flight times (i.e. neutron energies En > 3.5–6 MeV), possibly due to neutron elastic scattering off 12C; iii) events with large pulse height and flight times corresponding to En > 6 MeV mainly due to inelastic reactions such as 12C(n,α)9Be and 12C(n,n')3α. The potential use of this detector is discussed in relation to the ChipIr neutron beam line for fast neutron irradiation of electronic components at the ISIS spallation source.

Rebai, M., Giacomelli, L., Andreani, C., Fazzi, A., Frost, C., Cippo, E., et al. (2012). Diamond detectors for fast neutron measurements at pulsed spallation sources. JOURNAL OF INSTRUMENTATION, 7(05) [10.1088/1748-0221/7/05/C05015].

Diamond detectors for fast neutron measurements at pulsed spallation sources

REBAI, MARICA
;
GIACOMELLI, LUCA CARLO;GORINI, GIUSEPPE
2012

Abstract

The performance of a single crystal diamond (4.7x4.7x0.5mm3 active volume) detector was tested in the ISIS pulsed neutron beam using biparametric (time of flight and pulse height) data acquisition. Three characteristic regions in the biparametric spectra are observed: i) low pulse height events with very short time of flight induced by γ-rays; ii) low pulse height events at longer flight times (i.e. neutron energies En > 3.5–6 MeV), possibly due to neutron elastic scattering off 12C; iii) events with large pulse height and flight times corresponding to En > 6 MeV mainly due to inelastic reactions such as 12C(n,α)9Be and 12C(n,n')3α. The potential use of this detector is discussed in relation to the ChipIr neutron beam line for fast neutron irradiation of electronic components at the ISIS spallation source.
Articolo in rivista - Articolo scientifico
Instrumentation for neutron sources; Neutron detectors (cold, thermal, fast neutrons); Neutron sources; Solid state detectors
English
2012
7
05
C05015
none
Rebai, M., Giacomelli, L., Andreani, C., Fazzi, A., Frost, C., Cippo, E., et al. (2012). Diamond detectors for fast neutron measurements at pulsed spallation sources. JOURNAL OF INSTRUMENTATION, 7(05) [10.1088/1748-0221/7/05/C05015].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/39143
Citazioni
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 25
Social impact