The Silicon Vertex Tracker (SVT) of the BABAR experiment at the PEP-II asymmetric B factory is a crucial element of the BABAR physics program. The SVT is a five layer device with double-sided silicon strip detectors and a custom readout chip based on a time-over-threshold circuit. The SVT is fully operational since the installation in the experiment in 1999. We briefly review the detector performance after more than 3 years of data taking in factory mode. The high-luminosity running of PEP-II through the end of the decade will increase the radiation level in the SVT above its design limit. Radiation issues will be reviewed and results from radiation tests of the various detector components will be presented. We finally discuss the outlook for the long-term running of the SVT.

Re, V., Kirkby, D., Bruinsma, M., Berryhill, J., Burke, S., Callahan, D., et al. (2004). Sensor performance of the BABAR Silicon Vertex Tracker after 4 years of data taking. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 518(1-2), 286-289 [10.1016/j.nima.2003.11.001].

Sensor performance of the BABAR Silicon Vertex Tracker after 4 years of data taking

CARPINELLI, Massimo;
2004

Abstract

The Silicon Vertex Tracker (SVT) of the BABAR experiment at the PEP-II asymmetric B factory is a crucial element of the BABAR physics program. The SVT is a five layer device with double-sided silicon strip detectors and a custom readout chip based on a time-over-threshold circuit. The SVT is fully operational since the installation in the experiment in 1999. We briefly review the detector performance after more than 3 years of data taking in factory mode. The high-luminosity running of PEP-II through the end of the decade will increase the radiation level in the SVT above its design limit. Radiation issues will be reviewed and results from radiation tests of the various detector components will be presented. We finally discuss the outlook for the long-term running of the SVT.
Articolo in rivista - Articolo scientifico
Detector; Radiation; Vertex
English
2004
518
1-2
286
289
none
Re, V., Kirkby, D., Bruinsma, M., Berryhill, J., Burke, S., Callahan, D., et al. (2004). Sensor performance of the BABAR Silicon Vertex Tracker after 4 years of data taking. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 518(1-2), 286-289 [10.1016/j.nima.2003.11.001].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/389918
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 1
Social impact