Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
We present a measurement of the inclusive electron spectrum in B→Xueν decays near the kinematic limit for B→Xceν transitions, using a sample of 88×106 BB̄ pairs recorded by the BABAR detector at the Υ(4S) resonance. Partial branching fraction measurements are performed in five overlapping intervals of the electron momentum; for the interval of 2.0-2.6GeV/c we obtain ΔB(B→Xueν)=(0.572±0. 041stat±0.065syst)×10-3. Combining this result with shape function parameters extracted from BABAR measurements of moments of the inclusive photon spectrum in B→Xsγ decays and moments of the hadron-mass and lepton-energy spectra in B→Xcℓν decays we determine |Vub|=(4.44±0.25exp-0.38SF+0.42±0.22theory)×10-3. Here the first error represents the combined statistical and systematic experimental uncertainties of the partial branching fraction measurement, the second error refers to the uncertainty of the determination of the shape function parameters, and the third error is due to theoretical uncertainties in the QCD calculations.
Aubert, B., Barate, R., Boutigny, D., Couderc, F., Karyotakis, Y., Lees, J., et al. (2006). Measurement of the inclusive electron spectrum in charmless semileptonic B decays near the kinematic end point and determination of |Vub|. PHYSICAL REVIEW D, PARTICLES, FIELDS, GRAVITATION, AND COSMOLOGY, 73(1) [10.1103/PhysRevD.73.012006].
Measurement of the inclusive electron spectrum in charmless semileptonic B decays near the kinematic end point and determination of |Vub|
We present a measurement of the inclusive electron spectrum in B→Xueν decays near the kinematic limit for B→Xceν transitions, using a sample of 88×106 BB̄ pairs recorded by the BABAR detector at the Υ(4S) resonance. Partial branching fraction measurements are performed in five overlapping intervals of the electron momentum; for the interval of 2.0-2.6GeV/c we obtain ΔB(B→Xueν)=(0.572±0. 041stat±0.065syst)×10-3. Combining this result with shape function parameters extracted from BABAR measurements of moments of the inclusive photon spectrum in B→Xsγ decays and moments of the hadron-mass and lepton-energy spectra in B→Xcℓν decays we determine |Vub|=(4.44±0.25exp-0.38SF+0.42±0.22theory)×10-3. Here the first error represents the combined statistical and systematic experimental uncertainties of the partial branching fraction measurement, the second error refers to the uncertainty of the determination of the shape function parameters, and the third error is due to theoretical uncertainties in the QCD calculations.
Aubert, B., Barate, R., Boutigny, D., Couderc, F., Karyotakis, Y., Lees, J., et al. (2006). Measurement of the inclusive electron spectrum in charmless semileptonic B decays near the kinematic end point and determination of |Vub|. PHYSICAL REVIEW D, PARTICLES, FIELDS, GRAVITATION, AND COSMOLOGY, 73(1) [10.1103/PhysRevD.73.012006].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/389770
Citazioni
75
113
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2021-2023 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.