Single-shot in-line phase-contrast imaging with the Inverse Compton Scattering X-ray source available at ATF (Accelerator Test Facility) at Brookhaven National Laboratory is experimentally demonstrated. Phase-contrast images of polymer wires are obtained with a single X-ray pulse whose time length is about 1 picosecond. The edge-enhancement effect is clearly visible in the images and simulations show a quantitative agreement with experimental data. A phase-retrieval step in the image processing leads to a accurate estimation of the projected thickness of our samples. Finally, a single-shot image of a wasp is presented as an example of a biological sample.

Endrizzi, M., Carpinelli, M., Delogu, P., Oliva, P., Golosio, B., Gureyev, T., et al. (2010). X-ray phase-contrast imaging with an inverse compton scattering source. In 6th International Conference on Medical Applications of Synchrotron Radiation, MASR2010 (pp.39-41) [10.1063/1.3478194].

X-ray phase-contrast imaging with an inverse compton scattering source

CARPINELLI, Massimo;
2010

Abstract

Single-shot in-line phase-contrast imaging with the Inverse Compton Scattering X-ray source available at ATF (Accelerator Test Facility) at Brookhaven National Laboratory is experimentally demonstrated. Phase-contrast images of polymer wires are obtained with a single X-ray pulse whose time length is about 1 picosecond. The edge-enhancement effect is clearly visible in the images and simulations show a quantitative agreement with experimental data. A phase-retrieval step in the image processing leads to a accurate estimation of the projected thickness of our samples. Finally, a single-shot image of a wasp is presented as an example of a biological sample.
paper
Inverse Compton Scattering; phase-contrast imaging; X-ray imaging;
English
6th International Conference on Medical Applications of Synchrotron Radiation, MASR2010 - 15 February 2010 through 18 February 2010
2010
6th International Conference on Medical Applications of Synchrotron Radiation, MASR2010
978-0-7354-0813-5
2010
1266
39
41
none
Endrizzi, M., Carpinelli, M., Delogu, P., Oliva, P., Golosio, B., Gureyev, T., et al. (2010). X-ray phase-contrast imaging with an inverse compton scattering source. In 6th International Conference on Medical Applications of Synchrotron Radiation, MASR2010 (pp.39-41) [10.1063/1.3478194].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/389593
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
Social impact