Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

Endrizzi, M., Gureyev, T., Delogu, P., Oliva, P., Golosio, B., Carpinelli, M., et al. (2011). Quantitative phase retrieval with picosecond X-ray pulses from the ATF inverse compton scattering source. OPTICS EXPRESS, 19(3), 2748-2753 [10.1364/OE.19.002748].

Quantitative phase retrieval with picosecond X-ray pulses from the ATF inverse compton scattering source

Carpinelli, M;
2011

Abstract

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.
Articolo in rivista - Articolo scientifico
X-ray phase retrieval; Inverse Compton Scattering
English
2011
19
3
2748
2753
open
Endrizzi, M., Gureyev, T., Delogu, P., Oliva, P., Golosio, B., Carpinelli, M., et al. (2011). Quantitative phase retrieval with picosecond X-ray pulses from the ATF inverse compton scattering source. OPTICS EXPRESS, 19(3), 2748-2753 [10.1364/OE.19.002748].
File in questo prodotto:
File Dimensione Formato  
OpticExpress.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 811.95 kB
Formato Adobe PDF
811.95 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/389305
Citazioni
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
Social impact