The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at GSI has been designed to study carbon fragmentation, measuring 12C double differential cross sections (∂2σ/ ∂θ∂E) for different beam energies between 100 and 1000 MeV/u. The experimental setup integrates newly designed detectors in the, so called, Interaction Region around the graphite target. The Interaction Region upstream detectors are a 250 μm thick scintillator and a drift chamber optimized for a precise measurement of the ions interaction time and position on the target. In this article we review the design of the upstream detectors along with the preliminary results of the data taking performed on August 2011 with 400 MeV/u fully stripped carbon ion beam at GSI. Detectors performances will be reviewed and compared to those obtained during preliminary tests, performed with 500 MeV electrons (at the BTF facility in the INFN Frascati Laboratories) and 80 MeV/u protons and carbon ions (at the INFN LNS Laboratories in Catania).

Abou Haidar, Z., Agodi, C., Alvarez, M., Anelli, M., Aumann, T., Battistoni, G., et al. (2012). Performance of upstream interaction region detectors for the FIRST experiment at GSI. JOURNAL OF INSTRUMENTATION, 7(2) [10.1088/1748-0221/7/02/P02006].

Performance of upstream interaction region detectors for the FIRST experiment at GSI

CARPINELLI, Massimo;
2012

Abstract

The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at GSI has been designed to study carbon fragmentation, measuring 12C double differential cross sections (∂2σ/ ∂θ∂E) for different beam energies between 100 and 1000 MeV/u. The experimental setup integrates newly designed detectors in the, so called, Interaction Region around the graphite target. The Interaction Region upstream detectors are a 250 μm thick scintillator and a drift chamber optimized for a precise measurement of the ions interaction time and position on the target. In this article we review the design of the upstream detectors along with the preliminary results of the data taking performed on August 2011 with 400 MeV/u fully stripped carbon ion beam at GSI. Detectors performances will be reviewed and compared to those obtained during preliminary tests, performed with 500 MeV electrons (at the BTF facility in the INFN Frascati Laboratories) and 80 MeV/u protons and carbon ions (at the INFN LNS Laboratories in Catania).
Articolo in rivista - Articolo scientifico
Gaseous detectors; Particle tracking detectors (Gaseous detectors); Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators); Wire chambers (MWPC, Thin-gap chambers, drift chambers, drift tubes, proportional chambers etc);
English
2012
7
2
P02006
reserved
Abou Haidar, Z., Agodi, C., Alvarez, M., Anelli, M., Aumann, T., Battistoni, G., et al. (2012). Performance of upstream interaction region detectors for the FIRST experiment at GSI. JOURNAL OF INSTRUMENTATION, 7(2) [10.1088/1748-0221/7/02/P02006].
File in questo prodotto:
File Dimensione Formato  
JINST_2012.pdf

Solo gestori archivio

Descrizione: Article
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 2.51 MB
Formato Adobe PDF
2.51 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/389269
Citazioni
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 15
Social impact