Objectives: To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. Methods: Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular (LV) volumes and mass (LVM) using conventional and threshold-based segmentations. Phase-contrast images were used to independently measure stroke volume (SV). LV parameters were evaluated by two independent readers. Results: Evaluation times using the conventional and threshold-based methods were 8.4 ± 1.9 and 4.2 ± 1.3 min, respectively (P < 0.0001). LV parameters measured by the conventional and threshold-based methods, respectively, were end-diastolic volume (EDV) 146 ± 59 and 134 ± 53 ml; end-systolic volume (ESV) 64 ± 47 and 59 ± 46 ml; SV 82 ± 29 and 74 ± 28 ml (flow-based 74 ± 30 ml); ejection fraction (EF) 59 ± 16 and 58 ± 17 %; and LVM 141 ± 55 and 159 ± 58 g. Significant differences between the conventional and threshold-based methods were observed in EDV, ESV, and LVM mesurements; SV from threshold-based and flow-based measurements were in agreement (P > 0.05) but were significantly different from conventional analysis (P < 0.05). Excellent inter-observer agreement was observed. Conclusions: Threshold-based LV segmentation provides improved accuracy and faster assessment compared to conventional contour-based methods. Key Points: • Threshold-based left ventricular segmentation provides time-efficient assessment of left ventricular parameters • The threshold-based method can discriminate between blood and papillary muscles • This method provides improved accuracy compared to aortic flow measurements as a reference

Varga-Szemes, A., Muscogiuri, G., Schoepf, U., Wichmann, J., Suranyi, P., De Cecco, C., et al. (2016). Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method. EUROPEAN RADIOLOGY, 26(5), 1503-1511 [10.1007/s00330-015-3952-4].

Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method

Muscogiuri G;
2016

Abstract

Objectives: To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. Methods: Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular (LV) volumes and mass (LVM) using conventional and threshold-based segmentations. Phase-contrast images were used to independently measure stroke volume (SV). LV parameters were evaluated by two independent readers. Results: Evaluation times using the conventional and threshold-based methods were 8.4 ± 1.9 and 4.2 ± 1.3 min, respectively (P < 0.0001). LV parameters measured by the conventional and threshold-based methods, respectively, were end-diastolic volume (EDV) 146 ± 59 and 134 ± 53 ml; end-systolic volume (ESV) 64 ± 47 and 59 ± 46 ml; SV 82 ± 29 and 74 ± 28 ml (flow-based 74 ± 30 ml); ejection fraction (EF) 59 ± 16 and 58 ± 17 %; and LVM 141 ± 55 and 159 ± 58 g. Significant differences between the conventional and threshold-based methods were observed in EDV, ESV, and LVM mesurements; SV from threshold-based and flow-based measurements were in agreement (P > 0.05) but were significantly different from conventional analysis (P < 0.05). Excellent inter-observer agreement was observed. Conclusions: Threshold-based LV segmentation provides improved accuracy and faster assessment compared to conventional contour-based methods. Key Points: • Threshold-based left ventricular segmentation provides time-efficient assessment of left ventricular parameters • The threshold-based method can discriminate between blood and papillary muscles • This method provides improved accuracy compared to aortic flow measurements as a reference
Articolo in rivista - Articolo scientifico
Aortic flow; Cine magnetic resonance imaging; Left ventricular function; Left ventricular mass; Semi-automated segmentation;
English
2016
26
5
1503
1511
reserved
Varga-Szemes, A., Muscogiuri, G., Schoepf, U., Wichmann, J., Suranyi, P., De Cecco, C., et al. (2016). Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method. EUROPEAN RADIOLOGY, 26(5), 1503-1511 [10.1007/s00330-015-3952-4].
File in questo prodotto:
File Dimensione Formato  
Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 1.9 MB
Formato Adobe PDF
1.9 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/378295
Citazioni
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 31
Social impact