Objectives: To evaluate the influence of inversion time (TI) on the precision of myocardial late gadolinium enhancement (LGE) quantification using synthetic inversion recovery (IR) imaging in patients with myocardial infarction (MI). Methods: Fifty-three patients with suspected prior MI underwent 1.5-T cardiac MRI with conventional magnitude (MagIR) and phase-sensitive IR (PSIR) LGE imaging and T1 mapping at 15 min post-contrast. T1-based synthetic MagIR and PSIR images were calculated with a TI ranging from −100 to +150 ms at 5-ms intervals relative to the optimal TI (TI0). LGE was quantified using a five standard deviation (5SD) and full width at half-maximum (FWHM) thresholds. Measurements were compared using one-way analysis of variance. Results: The MagIRsy technique provided precise assessment of LGE area at TIs ≥ TI0, while precision was decreased below TI0. The LGE area showed significant differences at ≤ −25 ms compared to TI0 using 5SD (P < 0.001) and at ≤ −65 ms using the FWHM approach (P < 0.001). LGE measurements did not show significant difference over the analysed TI range in the PSIRsy images using either of the quantification methods. Conclusions: T1 map-based PSIRsy images provide precise quantification of MI independent of TI at the investigated time point post-contrast. MagIRsy-based MI quantification is precise at TI0 and at longer TIs while showing decreased precision at TI values below TI0. Key Points: • Synthetic IR imaging retrospectively generates LGE images at any theoretical TI • Synthetic IR imaging can simulate the effect of TI on LGE quantification • Fifteen minutes post-contrast MagIRsyaccurately quantifies infarcts from TI0to TI0 + 150 ms • Fifteen minutes post-contrast PSIRsyprovides precise infarct size independent of TI • Synthetic IR imaging has further advantages in reducing operator dependence.

Varga-Szemes, A., van der Geest, R., Schoepf, U., Spottiswoode, B., De Cecco, C., Muscogiuri, G., et al. (2017). Effect of inversion time on the precision of myocardial late gadolinium enhancement quantification evaluated with synthetic inversion recovery MR imaging. EUROPEAN RADIOLOGY, 27(8), 3235-3243 [10.1007/s00330-016-4665-z].

Effect of inversion time on the precision of myocardial late gadolinium enhancement quantification evaluated with synthetic inversion recovery MR imaging

Muscogiuri G;
2017

Abstract

Objectives: To evaluate the influence of inversion time (TI) on the precision of myocardial late gadolinium enhancement (LGE) quantification using synthetic inversion recovery (IR) imaging in patients with myocardial infarction (MI). Methods: Fifty-three patients with suspected prior MI underwent 1.5-T cardiac MRI with conventional magnitude (MagIR) and phase-sensitive IR (PSIR) LGE imaging and T1 mapping at 15 min post-contrast. T1-based synthetic MagIR and PSIR images were calculated with a TI ranging from −100 to +150 ms at 5-ms intervals relative to the optimal TI (TI0). LGE was quantified using a five standard deviation (5SD) and full width at half-maximum (FWHM) thresholds. Measurements were compared using one-way analysis of variance. Results: The MagIRsy technique provided precise assessment of LGE area at TIs ≥ TI0, while precision was decreased below TI0. The LGE area showed significant differences at ≤ −25 ms compared to TI0 using 5SD (P < 0.001) and at ≤ −65 ms using the FWHM approach (P < 0.001). LGE measurements did not show significant difference over the analysed TI range in the PSIRsy images using either of the quantification methods. Conclusions: T1 map-based PSIRsy images provide precise quantification of MI independent of TI at the investigated time point post-contrast. MagIRsy-based MI quantification is precise at TI0 and at longer TIs while showing decreased precision at TI values below TI0. Key Points: • Synthetic IR imaging retrospectively generates LGE images at any theoretical TI • Synthetic IR imaging can simulate the effect of TI on LGE quantification • Fifteen minutes post-contrast MagIRsyaccurately quantifies infarcts from TI0to TI0 + 150 ms • Fifteen minutes post-contrast PSIRsyprovides precise infarct size independent of TI • Synthetic IR imaging has further advantages in reducing operator dependence.
Articolo in rivista - Articolo scientifico
Cardiovascular magnetic resonance; Late gadolinium enhancement; Myocardial infarct; Synthetic inversion recovery; T1 mapping;
English
2017
27
8
3235
3243
reserved
Varga-Szemes, A., van der Geest, R., Schoepf, U., Spottiswoode, B., De Cecco, C., Muscogiuri, G., et al. (2017). Effect of inversion time on the precision of myocardial late gadolinium enhancement quantification evaluated with synthetic inversion recovery MR imaging. EUROPEAN RADIOLOGY, 27(8), 3235-3243 [10.1007/s00330-016-4665-z].
File in questo prodotto:
File Dimensione Formato  
Effect of inversion time on the precision of myocardial late gadolinium enhancement quantification evaluated with synthetic inversion recovery MR imaging.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 2.82 MB
Formato Adobe PDF
2.82 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/378170
Citazioni
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
Social impact