The effect of X-ray irradiation and thermal treatments on the radio-luminescence emission spectrum of both a natural pegmatitic quartz and a synthetic one was investigated. All the emission spectra could be deconvolved into the same set of five Gaussian components. Among the identified RL bands, a blue emission at 2.53 eV (480 nm) is enhanced under X-ray irradiation. A strong correlation with the sensitization of the so called "110 degrees C" TSL peak (in our measurements seen at lower temperature due to the lower heating rate) was proved, suggesting that the recombination centers associated with the 2.53 eV band are produced under X-ray irradiation and are involved in both RL and TSL luminescence mechanisms. When each irradiation was followed by heating up to 500 degrees C a strong sensitization of the RL band emitting at 3.44 eV and of the 110 degrees C TSL peak were observed. A perfect correlation between the RL and TSL emissions suggests that the recombination centers involved in the RL and TSL emissions are the same

Martini, M., Fasoli, M., Villa, I., Guibert, P. (2012). Radioluminescence of synthetic and natural quartz. RADIATION MEASUREMENTS, 47(9), 846-850 [10.1016/j.radmeas.2012.01.008].

Radioluminescence of synthetic and natural quartz

MARTINI, MARCO;FASOLI, MAURO;VILLA, IRENE;
2012

Abstract

The effect of X-ray irradiation and thermal treatments on the radio-luminescence emission spectrum of both a natural pegmatitic quartz and a synthetic one was investigated. All the emission spectra could be deconvolved into the same set of five Gaussian components. Among the identified RL bands, a blue emission at 2.53 eV (480 nm) is enhanced under X-ray irradiation. A strong correlation with the sensitization of the so called "110 degrees C" TSL peak (in our measurements seen at lower temperature due to the lower heating rate) was proved, suggesting that the recombination centers associated with the 2.53 eV band are produced under X-ray irradiation and are involved in both RL and TSL luminescence mechanisms. When each irradiation was followed by heating up to 500 degrees C a strong sensitization of the RL band emitting at 3.44 eV and of the 110 degrees C TSL peak were observed. A perfect correlation between the RL and TSL emissions suggests that the recombination centers involved in the RL and TSL emissions are the same
Articolo in rivista - Articolo scientifico
Quartz; radioluminescence; thermoluminescence
English
2012
47
9
846
850
none
Martini, M., Fasoli, M., Villa, I., Guibert, P. (2012). Radioluminescence of synthetic and natural quartz. RADIATION MEASUREMENTS, 47(9), 846-850 [10.1016/j.radmeas.2012.01.008].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/37015
Citazioni
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
Social impact