An high sensitivity vector-2D magnetic sensor system for low magnetic field measurements has been realized and tested. The system, realized in PCB technology, consists of a double axis Fluxgate magnetic sensor with its front-end electronic circuitry based on second-harmonic detection. The amorphous magnetic materials Vitrovac 6025X (25 mu m thick) and Vitrovac 6025Z (20 mu m thick) were used as a ferromagnetic core for the sensor. Applying a sinusoidal excitation current of 450 mA peak at 10 kHz with the Vitrovac 6025Z, the magnetic sensitivity was about 1.25 mV/mu T, suitable for detecting the Earth's magnetic field (+/- 60 mu T), while the linearity error is 1.5% full scale. Using the thicker Vitrovac 6025X, a maximum sensitivity of about 1.68 mV/mu T and a linearity error of about 1.55% full scale in the range of +/- 60 mu T were obtained with a larger sinusoidal excitation current of 600 mA peak at 10 kHz. The 2D vector sensor system presented is characterized by a very simple process fabrication due to the use of commercially available very thin ferromagnetic material.

Baschirotto, A., Dallago, E., Malcovati, P., Marchesi, M., Venchi, G. (2004). Precise Vector-2D Magnetic Field Sensor System for Electronic Compass. In Proceedings of IEEE International Conference on Sensors (Sensors `04) (pp.1028-1031). IEEE [10.1109/ICSENS.2004.1426349].

Precise Vector-2D Magnetic Field Sensor System for Electronic Compass

BASCHIROTTO, ANDREA;
2004

Abstract

An high sensitivity vector-2D magnetic sensor system for low magnetic field measurements has been realized and tested. The system, realized in PCB technology, consists of a double axis Fluxgate magnetic sensor with its front-end electronic circuitry based on second-harmonic detection. The amorphous magnetic materials Vitrovac 6025X (25 mu m thick) and Vitrovac 6025Z (20 mu m thick) were used as a ferromagnetic core for the sensor. Applying a sinusoidal excitation current of 450 mA peak at 10 kHz with the Vitrovac 6025Z, the magnetic sensitivity was about 1.25 mV/mu T, suitable for detecting the Earth's magnetic field (+/- 60 mu T), while the linearity error is 1.5% full scale. Using the thicker Vitrovac 6025X, a maximum sensitivity of about 1.68 mV/mu T and a linearity error of about 1.55% full scale in the range of +/- 60 mu T were obtained with a larger sinusoidal excitation current of 600 mA peak at 10 kHz. The 2D vector sensor system presented is characterized by a very simple process fabrication due to the use of commercially available very thin ferromagnetic material.
paper
Magnetic field sensor
English
Sensors
Proceedings of IEEE International Conference on Sensors (Sensors `04)
0-7803-8692-2
2004
1028
1031
none
Baschirotto, A., Dallago, E., Malcovati, P., Marchesi, M., Venchi, G. (2004). Precise Vector-2D Magnetic Field Sensor System for Electronic Compass. In Proceedings of IEEE International Conference on Sensors (Sensors `04) (pp.1028-1031). IEEE [10.1109/ICSENS.2004.1426349].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/36861
Citazioni
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 12
Social impact