The High Voltage Padova Test Facility is an experimental device realized to investigate the high voltage insulation in vacuum in support of the negative neutral beam injector prototype for ITER, MITICA. Moreover, the experiment aims to give a contribution on the understanding of the voltage holding in vacuum, as a physical phenomenon. Two stainless steel electrodes, with few cm of gap in a high vacuum chamber, achieve a saturation breakdown value (up to 400 kV) after about ten hours. A highly time resolved X-ray diagnostic has been recently installed in the device, measuring the X events (single events are detected) produced during the high voltage conditioning: high energy fluxes are observed in correspondence to the current peaks collected by the electrodes. This contribution presents a characterization of the current and X-ray emission events in terms of frequency, amplitude and their occurrence with respect to the voltage between the electrodes.

Spagnolo, S., Pilan, N., De Lorenzi, A., Lotto, L., Martines, E., Rossetto, F., et al. (2018). Current Signals and X- Ray Spectra Analysis for a Vacuum High Voltage Holding Experiment. In Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV (pp.89-92). Institute of Electrical and Electronics Engineers Inc. [10.1109/DEIV.2018.8537056].

Current Signals and X- Ray Spectra Analysis for a Vacuum High Voltage Holding Experiment

Martines E.;
2018

Abstract

The High Voltage Padova Test Facility is an experimental device realized to investigate the high voltage insulation in vacuum in support of the negative neutral beam injector prototype for ITER, MITICA. Moreover, the experiment aims to give a contribution on the understanding of the voltage holding in vacuum, as a physical phenomenon. Two stainless steel electrodes, with few cm of gap in a high vacuum chamber, achieve a saturation breakdown value (up to 400 kV) after about ten hours. A highly time resolved X-ray diagnostic has been recently installed in the device, measuring the X events (single events are detected) produced during the high voltage conditioning: high energy fluxes are observed in correspondence to the current peaks collected by the electrodes. This contribution presents a characterization of the current and X-ray emission events in terms of frequency, amplitude and their occurrence with respect to the voltage between the electrodes.
paper
large gaps; voltage holding; X-rays spectra;
English
28th International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV 2018 - SEP 23-28, 2018
2018
Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV
978-1-5386-4375-4
2018
1
89
92
8537056
reserved
Spagnolo, S., Pilan, N., De Lorenzi, A., Lotto, L., Martines, E., Rossetto, F., et al. (2018). Current Signals and X- Ray Spectra Analysis for a Vacuum High Voltage Holding Experiment. In Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV (pp.89-92). Institute of Electrical and Electronics Engineers Inc. [10.1109/DEIV.2018.8537056].
File in questo prodotto:
File Dimensione Formato  
109 - ISDEIV 18 Xray events.pdf

Solo gestori archivio

Descrizione: Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 729.33 kB
Formato Adobe PDF
729.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia