An emissive probe has been used in the edge region of the CASTOR tokamak in order to test the possibility of direct measurements of the plasma potential. The difference between the floating potential of a cold probe and that of an emissive probe has been found to be approximately 1.3 times the electron temperature, which is less than predicted by the probe theory. Several possible reasons to explain this discrepancy are offered, such as secondary electron emission, uncertainties in the ion temperature, different collecting areas for electrons and ions, etc. The possible impact of a space charge formed by the emitted electrons is also discussed.

Schrittwieser, R., Adamek, J., Balan, P., Hron, M., Ionita, C., Jakubka, K., et al. (2002). Measurements with an emissive probe in the CASTOR tokamak. PLASMA PHYSICS AND CONTROLLED FUSION, 44(5), 567-578 [10.1088/0741-3335/44/5/305].

Measurements with an emissive probe in the CASTOR tokamak

Martines E;
2002

Abstract

An emissive probe has been used in the edge region of the CASTOR tokamak in order to test the possibility of direct measurements of the plasma potential. The difference between the floating potential of a cold probe and that of an emissive probe has been found to be approximately 1.3 times the electron temperature, which is less than predicted by the probe theory. Several possible reasons to explain this discrepancy are offered, such as secondary electron emission, uncertainties in the ion temperature, different collecting areas for electrons and ions, etc. The possible impact of a space charge formed by the emitted electrons is also discussed.
Articolo in rivista - Articolo scientifico
tokamak; Castor; emissive probes; plasma potential;
English
2002
44
5
567
578
reserved
Schrittwieser, R., Adamek, J., Balan, P., Hron, M., Ionita, C., Jakubka, K., et al. (2002). Measurements with an emissive probe in the CASTOR tokamak. PLASMA PHYSICS AND CONTROLLED FUSION, 44(5), 567-578 [10.1088/0741-3335/44/5/305].
File in questo prodotto:
File Dimensione Formato  
046 - PPCF 02 emissive probes Castor.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 176.35 kB
Formato Adobe PDF
176.35 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/365886
Citazioni
  • Scopus 95
  • ???jsp.display-item.citation.isi??? 89
Social impact