ICARUS T600 will become the far detector of the Short Baseline Neutrino program at FNAL (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line. The apparatus is now under refurbishing at CERN. A new light detection system is foreseen, using four planes of photo-multiplier tubes (PMTs) with 90 units each. A first pre-series of 20 PMTs Hamamatsu R5912-MOD, 8 in. diameter suitable for cryogenic applications, was fully tested, both at room and at liquid argon temperature, to ensure good performance of the detector.

Raselli, G., Babicz, M., Bellini, V., Bonesini, M., Cervi, T., Falcone, A., et al. (2017). Test and Characterization of 20 Pre-series Hamamatsu R5916-MOD photomultiplier tubes for the ICARUS T600 detector. In 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 (pp.1-5). 345 E 47TH ST, NEW YORK, NY 10017 USA : Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2016.8069768].

Test and Characterization of 20 Pre-series Hamamatsu R5916-MOD photomultiplier tubes for the ICARUS T600 detector

Falcone A.;Spanu M.;Torti M.;
2017

Abstract

ICARUS T600 will become the far detector of the Short Baseline Neutrino program at FNAL (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line. The apparatus is now under refurbishing at CERN. A new light detection system is foreseen, using four planes of photo-multiplier tubes (PMTs) with 90 units each. A first pre-series of 20 PMTs Hamamatsu R5912-MOD, 8 in. diameter suitable for cryogenic applications, was fully tested, both at room and at liquid argon temperature, to ensure good performance of the detector.
paper
Photo detector
English
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
2016
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
978-1-5090-1642-6
2017
2017-
1
5
8069768
none
Raselli, G., Babicz, M., Bellini, V., Bonesini, M., Cervi, T., Falcone, A., et al. (2017). Test and Characterization of 20 Pre-series Hamamatsu R5916-MOD photomultiplier tubes for the ICARUS T600 detector. In 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 (pp.1-5). 345 E 47TH ST, NEW YORK, NY 10017 USA : Institute of Electrical and Electronics Engineers Inc. [10.1109/NSSMIC.2016.8069768].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/357799
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
Social impact