Liquid argon Time Projection Chambers (LAr-TPCs) are among the most promising detectors for the study of neutrino oscillations. They are composed by a multi-wire drift chamber to collect the charge and a photodetection system to detect the scintillation light, both produced by ionizing charged particles that cross the argon volume. Scintillation light plays a fundamental role for the event reconstruction because it permits to calculate the absolute time t0 of the event and it is also used for triggering purposes. We present a comparison between the performances of large area Photo-Multiplier Tubes (PMTs) and Silicon Photo-Multiplier (SiPM) arrays deployed in a small LAr-TPC exposed to cosmic rays at CERN, both in terms of light collected and timing performances.

Cervi, T., Babicz, M., Bonesini, M., Falcone, A., Kose, U., Menegolli, A., et al. (2018). Comparison between large area PMTs and SiPM arrays deployed in a Liquid Argon Time Projection Chamber at CERN. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 912, 101-104 [10.1016/j.nima.2017.10.069].

Comparison between large area PMTs and SiPM arrays deployed in a Liquid Argon Time Projection Chamber at CERN

Bonesini M.;Falcone A.;Torti M.;
2018

Abstract

Liquid argon Time Projection Chambers (LAr-TPCs) are among the most promising detectors for the study of neutrino oscillations. They are composed by a multi-wire drift chamber to collect the charge and a photodetection system to detect the scintillation light, both produced by ionizing charged particles that cross the argon volume. Scintillation light plays a fundamental role for the event reconstruction because it permits to calculate the absolute time t0 of the event and it is also used for triggering purposes. We present a comparison between the performances of large area Photo-Multiplier Tubes (PMTs) and Silicon Photo-Multiplier (SiPM) arrays deployed in a small LAr-TPC exposed to cosmic rays at CERN, both in terms of light collected and timing performances.
Articolo in rivista - Articolo scientifico
Array; Cryogenic; LAr-TPC; PMT; SiliconPM; SiPM;
English
2018
912
101
104
none
Cervi, T., Babicz, M., Bonesini, M., Falcone, A., Kose, U., Menegolli, A., et al. (2018). Comparison between large area PMTs and SiPM arrays deployed in a Liquid Argon Time Projection Chamber at CERN. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 912, 101-104 [10.1016/j.nima.2017.10.069].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/357779
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact