Objective interpretation of FC results may still be hampered by limited technical stan-dardization. The EuroFlow consortium conducted a series of experiments to determine the impact of different variables on the relative distribution and the median fluorescence intensity (MFI) of markers stained on different cell populations, from both healthy donors and patients’ samples with distinct hematological malignancies. The use of different anticoagulants; the time interval between sample collection, preparation, and acquisition; pH of washing buffers; and the use of cell surface membrane-only (SM) vs. cell surface plus intracytoplasmic (SM+CY) staining protocols, were evaluated. Our results showed that only monocytes were represented at higher percentages in EDTA-vs. heparin-anticoagulated samples. Application of SM or SM+CY protocols resulted in slight differences in the percentage of neutrophils and debris determined only with particular antibody combinations. In turn, storage of samples for 24 h at RT was associated with greater percentage of debris and cell doublets when the plasma cell disorder panel was used. Furthermore, 24 h storage of stained cells at RT was selectively detrimental for MFI levels of CD19 and CD45 on mature B-and T-cells (but not on leukemic blasts, clonal B-and plasma cells, neutrophils, and NK cells). The obtained results showed that the variables evaluated might need to be tailored for sample and cell type(s) as well as to the specific markers compared; however, defining of well-balanced boundaries for storage time, staining-to-acquisition delay, and pH of washing buffer would be a valid recommendation for most applications and circumstances described herein.

Sedek, L., Flores-Montero, J., van der Sluijs, A., Kulis, J., Marvelde, J., Philippe, J., et al. (2022). Impact of Pre-Analytical and Analytical Variables Associated with Sample Preparation on Flow Cytometric Stainings Obtained with EuroFlow Panels. CANCERS, 14(3) [10.3390/cancers14030473].

Impact of Pre-Analytical and Analytical Variables Associated with Sample Preparation on Flow Cytometric Stainings Obtained with EuroFlow Panels

Buracchi C.;
2022

Abstract

Objective interpretation of FC results may still be hampered by limited technical stan-dardization. The EuroFlow consortium conducted a series of experiments to determine the impact of different variables on the relative distribution and the median fluorescence intensity (MFI) of markers stained on different cell populations, from both healthy donors and patients’ samples with distinct hematological malignancies. The use of different anticoagulants; the time interval between sample collection, preparation, and acquisition; pH of washing buffers; and the use of cell surface membrane-only (SM) vs. cell surface plus intracytoplasmic (SM+CY) staining protocols, were evaluated. Our results showed that only monocytes were represented at higher percentages in EDTA-vs. heparin-anticoagulated samples. Application of SM or SM+CY protocols resulted in slight differences in the percentage of neutrophils and debris determined only with particular antibody combinations. In turn, storage of samples for 24 h at RT was associated with greater percentage of debris and cell doublets when the plasma cell disorder panel was used. Furthermore, 24 h storage of stained cells at RT was selectively detrimental for MFI levels of CD19 and CD45 on mature B-and T-cells (but not on leukemic blasts, clonal B-and plasma cells, neutrophils, and NK cells). The obtained results showed that the variables evaluated might need to be tailored for sample and cell type(s) as well as to the specific markers compared; however, defining of well-balanced boundaries for storage time, staining-to-acquisition delay, and pH of washing buffer would be a valid recommendation for most applications and circumstances described herein.
Articolo in rivista - Articolo scientifico
Anticoagulant; Flow cytometry; Immunophenotyping; Leukemia; Lymphoma; Multiple myeloma; Protocol; Sample storage; Standardization;
English
18-gen-2022
2022
14
3
473
none
Sedek, L., Flores-Montero, J., van der Sluijs, A., Kulis, J., Marvelde, J., Philippe, J., et al. (2022). Impact of Pre-Analytical and Analytical Variables Associated with Sample Preparation on Flow Cytometric Stainings Obtained with EuroFlow Panels. CANCERS, 14(3) [10.3390/cancers14030473].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/353468
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
Social impact