The SYRMEP approach to digital mammography implies the use of a monochromatic X-ray beam from a synchrotron source and a slot of superimposed silicon microstrip detectors as a scanning image receptor. The microstrips are read by 32-channel chips mounted on 7-layer hybrid circuits which receive control signals and operating voltages from a MASTER-SLAVE configuration of cards. The MASTER card is driven by the CIRM, a dedicated CAMAC module whose timing function can be easily excluded to obtain data-storage-only units connected to different MASTERs: this second-level modular expansion capability fully achieves the tasks of an electronics system able to follow the SYRMEP detector growth till the final size of seven thousands of channels.

Arfelli, F., Bonvicini, V., Bravin, A., Cantatore, G., Castelli, E., Cristaudo, P., et al. (1998). SYRMEP front-end and read-out electronics. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 409(1-3), 351-353 [10.1016/S0168-9002(97)01297-7].

SYRMEP front-end and read-out electronics

Bravin A
Membro del Collaboration Group
;
1998

Abstract

The SYRMEP approach to digital mammography implies the use of a monochromatic X-ray beam from a synchrotron source and a slot of superimposed silicon microstrip detectors as a scanning image receptor. The microstrips are read by 32-channel chips mounted on 7-layer hybrid circuits which receive control signals and operating voltages from a MASTER-SLAVE configuration of cards. The MASTER card is driven by the CIRM, a dedicated CAMAC module whose timing function can be easily excluded to obtain data-storage-only units connected to different MASTERs: this second-level modular expansion capability fully achieves the tasks of an electronics system able to follow the SYRMEP detector growth till the final size of seven thousands of channels.
Articolo in rivista - Articolo scientifico
Electronics; Silicon detectors;
English
1998
409
1-3
351
353
reserved
Arfelli, F., Bonvicini, V., Bravin, A., Cantatore, G., Castelli, E., Cristaudo, P., et al. (1998). SYRMEP front-end and read-out electronics. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 409(1-3), 351-353 [10.1016/S0168-9002(97)01297-7].
File in questo prodotto:
File Dimensione Formato  
Arfelli_NIMA_1998.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 455.27 kB
Formato Adobe PDF
455.27 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/349024
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 5
Social impact