We present here the latest results from tests performed at the ESRF ID17 and ID21 beamlines for the characterization of novel beam monitors for Microbeam Radiation Therapy (MRT), which is currently being implemented at ID17. MRT aims at treating solid tumors by exploiting an array of evenly spaced microbeams, having an energy spectrum distributed between 27 and 600 keV and peaking at 100 keV. Given the high instantaneous dose delivered (up to 20 kGy/s), the position and the intensity of the microbeams has to be precisely and instantly monitored. For this purpose, we developed dedicated silicon microstrip beam monitors. We have successfully characterized them, both with a microbeam array at ID17, and a submicron scanning beam at ID21. We present here the latest results obtained in recent tests along with an outlook on future developments.

Alagoz, E., Brauer-Krisch, E., Bravin, A., Cornelius, I., Fournier, P., Hansen, T., et al. (2016). Multi-strip silicon sensors for beam array monitoring in micro-beam radiation therapy. PHYSICA MEDICA, 32(12), 1795-1800 [10.1016/j.ejmp.2016.11.005].

Multi-strip silicon sensors for beam array monitoring in micro-beam radiation therapy

Bravin A
Membro del Collaboration Group
;
2016

Abstract

We present here the latest results from tests performed at the ESRF ID17 and ID21 beamlines for the characterization of novel beam monitors for Microbeam Radiation Therapy (MRT), which is currently being implemented at ID17. MRT aims at treating solid tumors by exploiting an array of evenly spaced microbeams, having an energy spectrum distributed between 27 and 600 keV and peaking at 100 keV. Given the high instantaneous dose delivered (up to 20 kGy/s), the position and the intensity of the microbeams has to be precisely and instantly monitored. For this purpose, we developed dedicated silicon microstrip beam monitors. We have successfully characterized them, both with a microbeam array at ID17, and a submicron scanning beam at ID21. We present here the latest results obtained in recent tests along with an outlook on future developments.
Articolo in rivista - Articolo scientifico
Beam monitor; Micro-beam radiation therapy; Silicon; Synchrotron radiation;
English
2016
32
12
1795
1800
reserved
Alagoz, E., Brauer-Krisch, E., Bravin, A., Cornelius, I., Fournier, P., Hansen, T., et al. (2016). Multi-strip silicon sensors for beam array monitoring in micro-beam radiation therapy. PHYSICA MEDICA, 32(12), 1795-1800 [10.1016/j.ejmp.2016.11.005].
File in questo prodotto:
File Dimensione Formato  
Alagoz_PhysMed_2016.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 2.57 MB
Formato Adobe PDF
2.57 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/348294
Citazioni
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
Social impact