The SYRMEP project (SYnchrotron Radiation for MEdical Physics) intends to improve mammography performances using two non-traditional means: synchrotron radiation and silicon detectors. A silicon crystal (the monochromator) allows to choose the optimal beam energy that leads to the maximum signal to noise ratio, while the detectors are arranged to form a matrix of pixels and coupled to low noise high-gain VLSI integrated circuits making the single photon counting technique possible. We present the data acquisition system implemented to read out the VLSI circuit with particular emphasis on two dedicated CAMAC modules that generate the control signals and store the chip digital output on memories that can be accessed via the CAMAC bus. It has been useful in testing the chip performances and can be considered a prototype of the final SYRMEP data acquisition system.

Arfelli, F., Barbiellini, G., Bonvicini, V., Bravin, A., Cantatore, G., Castelli, E., et al. (1997). A digital readout system for the SYRMEP silicon strip detectors. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 392(1-3), 392-395 [10.1016/S0168-9002(97)00225-8].

A digital readout system for the SYRMEP silicon strip detectors

Bravin A;
1997

Abstract

The SYRMEP project (SYnchrotron Radiation for MEdical Physics) intends to improve mammography performances using two non-traditional means: synchrotron radiation and silicon detectors. A silicon crystal (the monochromator) allows to choose the optimal beam energy that leads to the maximum signal to noise ratio, while the detectors are arranged to form a matrix of pixels and coupled to low noise high-gain VLSI integrated circuits making the single photon counting technique possible. We present the data acquisition system implemented to read out the VLSI circuit with particular emphasis on two dedicated CAMAC modules that generate the control signals and store the chip digital output on memories that can be accessed via the CAMAC bus. It has been useful in testing the chip performances and can be considered a prototype of the final SYRMEP data acquisition system.
Articolo in rivista - Articolo scientifico
digital readout; silicon strip; detector; X-rays;
English
19-mag-1998
1997
392
1-3
392
395
reserved
Arfelli, F., Barbiellini, G., Bonvicini, V., Bravin, A., Cantatore, G., Castelli, E., et al. (1997). A digital readout system for the SYRMEP silicon strip detectors. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 392(1-3), 392-395 [10.1016/S0168-9002(97)00225-8].
File in questo prodotto:
File Dimensione Formato  
Arfelli_NIMA_1997.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 307.39 kB
Formato Adobe PDF
307.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/348053
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
Social impact