A hybrid approach was developed to compute the dose deposited in cancerous and healthy tissues during stereotactic synchrotron radiation therapy treatment. The proposed approach divides the computation into two parts: (1) the dose deposited by primary radiation (coming directly from the incident X-ray beam) is calculated using a deterministic algorithm based on ray casting, optimized for transport in voxelized geometries; (2) the dose deposited by secondary radiation (Rayleigh and Compton scattering, fluorescence) is computed using a hybrid algorithm combining Monte Carlo and deterministic calculations. In the Monte Carlo part, a set of scattering and fluorescence events occurring in the patient is determined. These events are further processed in a deterministic way, which considerably improves the statistics of the final dose map. The results obtained in test cases are compared to those obtained with the Monte Carlo method alone (Geant4 and MCNPX codes) and found to be in excellent agreement. The proposed simulation scheme makes it possible to simulate dose maps with a single PC, featuring computation time and statistical fluctuations substantially reduced in comparison with full Monte Carlo simulations.

Freud, N., Letang Jean, M., Mary, C., Boudou, C., Ferrero, C., Elleaume, H., et al. (2008). A hybrid approach for fast simulation of dose deposition in stereotactic synchrotron radiotherapy. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 55(3), 1008-1017 [10.1109/TNS.2008.922831].

A hybrid approach for fast simulation of dose deposition in stereotactic synchrotron radiotherapy

Bravin A
Membro del Collaboration Group
;
2008

Abstract

A hybrid approach was developed to compute the dose deposited in cancerous and healthy tissues during stereotactic synchrotron radiation therapy treatment. The proposed approach divides the computation into two parts: (1) the dose deposited by primary radiation (coming directly from the incident X-ray beam) is calculated using a deterministic algorithm based on ray casting, optimized for transport in voxelized geometries; (2) the dose deposited by secondary radiation (Rayleigh and Compton scattering, fluorescence) is computed using a hybrid algorithm combining Monte Carlo and deterministic calculations. In the Monte Carlo part, a set of scattering and fluorescence events occurring in the patient is determined. These events are further processed in a deterministic way, which considerably improves the statistics of the final dose map. The results obtained in test cases are compared to those obtained with the Monte Carlo method alone (Geant4 and MCNPX codes) and found to be in excellent agreement. The proposed simulation scheme makes it possible to simulate dose maps with a single PC, featuring computation time and statistical fluctuations substantially reduced in comparison with full Monte Carlo simulations.
Articolo in rivista - Articolo scientifico
Deterministic simulation; Dose calculation; Fluorescence; Hybrid simulation; Monte Carlo method; Ray casting; Rayleigh and Compton scattering; Stereotactic synchrotron radiation therapy; Treatment planning;
English
2008
55
3
1008
1017
4545117
reserved
Freud, N., Letang Jean, M., Mary, C., Boudou, C., Ferrero, C., Elleaume, H., et al. (2008). A hybrid approach for fast simulation of dose deposition in stereotactic synchrotron radiotherapy. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 55(3), 1008-1017 [10.1109/TNS.2008.922831].
File in questo prodotto:
File Dimensione Formato  
Freud_TNS_2008.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/347859
Citazioni
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
Social impact