The detection system is a key part of any imaging station. Here the performance of the novel sCMOS-based detection system installed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility and dedicated to high-resolution computed-tomography imaging is analysed. The system consists of an X-ray-visible-light converter, a visible-light optics and a PCO.Edge5.5 sCMOS detector. Measurements of the optical characteristics, the linearity of the system, the detection lag, the modulation transfer function, the normalized power spectrum, the detective quantum efficiency and the photon transfer curve are presented and discussed. The study was carried out at two different X-ray energies (35 and 50keV) using both 2× and 1× optical magnification systems. The final pixel size resulted in 3.1 and 6.2μm, respectively. The measured characteristic parameters of the PCO.Edge5.5 are in good agreement with the manufacturer specifications. Fast imaging can be achieved using this detection system, but at the price of unavoidable losses in terms of image quality. The way in which the X-ray beam inhomogeneity limited some of the performances of the system is also discussed.The detection system is a key part of any imaging station. Here the performance of the novel sCMOS-based detection system installed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility and dedicated to high-resolution computed-tomography imaging is analysed.

Mittone, A., Manakov, I., Broche, L., Jarnias, C., Coan, P., Bravin, A. (2017). Characterization of a sCMOS-based high-resolution imaging system. JOURNAL OF SYNCHROTRON RADIATION, 24(6), 1226-1236 [10.1107/S160057751701222X].

Characterization of a sCMOS-based high-resolution imaging system

Bravin A
Ultimo
Membro del Collaboration Group
2017

Abstract

The detection system is a key part of any imaging station. Here the performance of the novel sCMOS-based detection system installed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility and dedicated to high-resolution computed-tomography imaging is analysed. The system consists of an X-ray-visible-light converter, a visible-light optics and a PCO.Edge5.5 sCMOS detector. Measurements of the optical characteristics, the linearity of the system, the detection lag, the modulation transfer function, the normalized power spectrum, the detective quantum efficiency and the photon transfer curve are presented and discussed. The study was carried out at two different X-ray energies (35 and 50keV) using both 2× and 1× optical magnification systems. The final pixel size resulted in 3.1 and 6.2μm, respectively. The measured characteristic parameters of the PCO.Edge5.5 are in good agreement with the manufacturer specifications. Fast imaging can be achieved using this detection system, but at the price of unavoidable losses in terms of image quality. The way in which the X-ray beam inhomogeneity limited some of the performances of the system is also discussed.The detection system is a key part of any imaging station. Here the performance of the novel sCMOS-based detection system installed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility and dedicated to high-resolution computed-tomography imaging is analysed.
Articolo in rivista - Articolo scientifico
image detector; image quality; X-ray imaging;
English
2017
24
6
1226
1236
reserved
Mittone, A., Manakov, I., Broche, L., Jarnias, C., Coan, P., Bravin, A. (2017). Characterization of a sCMOS-based high-resolution imaging system. JOURNAL OF SYNCHROTRON RADIATION, 24(6), 1226-1236 [10.1107/S160057751701222X].
File in questo prodotto:
File Dimensione Formato  
Mittone_JSR_2017.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 1.93 MB
Formato Adobe PDF
1.93 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/345378
Citazioni
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 41
Social impact