The purpose of this work is to define safe irradiation protocols in microbeam radiation therapy. The intense synchrotron-generated x-ray beam used for the treatment is collimated and delivered in an array of 50 μm-sized rectangular fields with a centre-to-centre distance between microplanes of 400 μm. The absorbed doses received by the tumour and the healthy tissues in a human head phantom have been assessed by means of Monte Carlo simulations. The identification of safe dose limits is carried out by evaluating the maximum peak and valley doses achievable in the tumour while keeping the valley doses in the healthy tissues under tolerances. As the skull receives a significant fraction of the dose, the dose limits are referred to this tissue. Dose distributions with high spatial resolution are presented for various tumour positions, skull thicknesses and interbeam separations. Considering a unidirectional irradiation (field size of 2×2 cm2) and a centrally located tumour, the largest peak and valley doses achievable in the tumour are 55 Gy and 2.6 Gy, respectively. The corresponding maximum valley doses received by the skin, bone and healthy brain are 4 Gy, 14 Gy and 7 Gy (doses in one fraction), respectively, i.e. within tolerances (5% probability of complication within 5 years).

Martinez-Rovira, I., Sempau, J., Fernandez-Varea, J., Bravin, A., Prezado, Y. (2010). Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy. PHYSICS IN MEDICINE AND BIOLOGY, 55(15), 4375-4388 [10.1088/0031-9155/55/15/012].

Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy

Bravin A
Penultimo
Membro del Collaboration Group
;
2010

Abstract

The purpose of this work is to define safe irradiation protocols in microbeam radiation therapy. The intense synchrotron-generated x-ray beam used for the treatment is collimated and delivered in an array of 50 μm-sized rectangular fields with a centre-to-centre distance between microplanes of 400 μm. The absorbed doses received by the tumour and the healthy tissues in a human head phantom have been assessed by means of Monte Carlo simulations. The identification of safe dose limits is carried out by evaluating the maximum peak and valley doses achievable in the tumour while keeping the valley doses in the healthy tissues under tolerances. As the skull receives a significant fraction of the dose, the dose limits are referred to this tissue. Dose distributions with high spatial resolution are presented for various tumour positions, skull thicknesses and interbeam separations. Considering a unidirectional irradiation (field size of 2×2 cm2) and a centrally located tumour, the largest peak and valley doses achievable in the tumour are 55 Gy and 2.6 Gy, respectively. The corresponding maximum valley doses received by the skin, bone and healthy brain are 4 Gy, 14 Gy and 7 Gy (doses in one fraction), respectively, i.e. within tolerances (5% probability of complication within 5 years).
Articolo in rivista - Articolo scientifico
Monte Carlo dosimetry, clinical trials, x-rays, microbeam radiation therapy
English
2010
55
15
4375
4388
reserved
Martinez-Rovira, I., Sempau, J., Fernandez-Varea, J., Bravin, A., Prezado, Y. (2010). Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy. PHYSICS IN MEDICINE AND BIOLOGY, 55(15), 4375-4388 [10.1088/0031-9155/55/15/012].
File in questo prodotto:
File Dimensione Formato  
Rovira_PMB_2010.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 381.58 kB
Formato Adobe PDF
381.58 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/343194
Citazioni
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 41
Social impact