A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-stent restenosis. For each patient, diagnosis has been performed on the synchrotron radiation images and monitored with the conventional selective coronary angiography method taken as the golden standard. In this paper, the methods of image processing and the results of the quantitative analysis are described. Image processing includes beam harmonic contamination correction, spatial deconvolution and the extraction of a 'contrast' and a 'tissue' image from each couple of radiograms simultaneously acquired at energies bracketing the K-edge of iodine. Quantitative analysis includes the estimation of the vessel diameter, the calculation of the absolute iodine concentration profiles along the coronary arteries and the stenosis degree measurement.

Sarnelli, A., Nemoz, C., Elleaume, N., Esteve, F., Bertrand, B., Bravin, A. (2005). Quantitative analysis of synchrotron radiation intravenous angiographic images. PHYSICS IN MEDICINE AND BIOLOGY, 50(4), 725-740 [10.1088/0031-9155/50/4/011].

Quantitative analysis of synchrotron radiation intravenous angiographic images

Bravin A
Ultimo
Membro del Collaboration Group
2005

Abstract

A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-stent restenosis. For each patient, diagnosis has been performed on the synchrotron radiation images and monitored with the conventional selective coronary angiography method taken as the golden standard. In this paper, the methods of image processing and the results of the quantitative analysis are described. Image processing includes beam harmonic contamination correction, spatial deconvolution and the extraction of a 'contrast' and a 'tissue' image from each couple of radiograms simultaneously acquired at energies bracketing the K-edge of iodine. Quantitative analysis includes the estimation of the vessel diameter, the calculation of the absolute iodine concentration profiles along the coronary arteries and the stenosis degree measurement.
Articolo in rivista - Articolo scientifico
Quantitative analysis, synchrotron radiation, intravenous angiography
English
2005
50
4
725
740
reserved
Sarnelli, A., Nemoz, C., Elleaume, N., Esteve, F., Bertrand, B., Bravin, A. (2005). Quantitative analysis of synchrotron radiation intravenous angiographic images. PHYSICS IN MEDICINE AND BIOLOGY, 50(4), 725-740 [10.1088/0031-9155/50/4/011].
File in questo prodotto:
File Dimensione Formato  
sarnelli-pmb5_4_011.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/343192
Citazioni
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 19
Social impact