Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml-1 and 1.34 mg ml-1 for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml-1 and 1.31 mg ml-1. With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml-1 (8 mm diameter) and 5.75 mg ml-1 (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml-1 (8 mm diameter) and 1.57 mg ml-1 (5 mm diameter).

Baldelli, P., Bravin, A., Di Maggio, C., Gennaro, G., Sarnelli, A., Taibi, A., et al. (2006). Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography. PHYSICS IN MEDICINE AND BIOLOGY, 51(17), 4233-4251 [10.1088/0031-9155/51/17/008].

Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography

Bravin A
Secondo
Membro del Collaboration Group
;
2006

Abstract

Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml-1 and 1.34 mg ml-1 for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml-1 and 1.31 mg ml-1. With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml-1 (8 mm diameter) and 5.75 mg ml-1 (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml-1 (8 mm diameter) and 1.57 mg ml-1 (5 mm diameter).
Articolo in rivista - Articolo scientifico
contrast-enhanced subtraction mammography, iodine
English
2006
51
17
4233
4251
reserved
Baldelli, P., Bravin, A., Di Maggio, C., Gennaro, G., Sarnelli, A., Taibi, A., et al. (2006). Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography. PHYSICS IN MEDICINE AND BIOLOGY, 51(17), 4233-4251 [10.1088/0031-9155/51/17/008].
File in questo prodotto:
File Dimensione Formato  
baldelli-pmb6_17_008.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 411.57 kB
Formato Adobe PDF
411.57 kB Adobe PDF   Visualizza/Apri   Richiedi una copia