Clinical microbeam radiation therapy (MRT) will require a multislit collimator with adjustable uniform slit widths to enable reliable Monte Carlo-based treatment planning. Such a collimator has been designed, fabricated of >99% tungsten [W] by Tecomet/Viasys (Woburn, Massachusetts, USA) and installed at the 6 GeV electron-wiggler-generated hard x-ray ID17 beamline of the European Synchrotron Radiation Facility. Its pair of 125 parallel, 8 mm deep, 0.100 mm wide radiolucent slits, 0.400 mm on center, are perfused with nitrogen gas [N2] to dissipate heat during irradiation. Major improvements in uniformity of microbeam widths and good peak/valley dose ratios combined with a very high dose rate in targeted tissues have been achieved.

Brauer-Krisch, E., Bravin, A., Zhang, L., Siegbahn, E., Stepanek, J., Blattmann, H., et al. (2005). Characterization of a tungsten/gas multislit collimator for microbeam radiation therapy at the European Synchrotron Radiation Facility. REVIEW OF SCIENTIFIC INSTRUMENTS, 76(6) [10.1063/1.1915270].

Characterization of a tungsten/gas multislit collimator for microbeam radiation therapy at the European Synchrotron Radiation Facility

Bravin A
Secondo
Membro del Collaboration Group
;
2005

Abstract

Clinical microbeam radiation therapy (MRT) will require a multislit collimator with adjustable uniform slit widths to enable reliable Monte Carlo-based treatment planning. Such a collimator has been designed, fabricated of >99% tungsten [W] by Tecomet/Viasys (Woburn, Massachusetts, USA) and installed at the 6 GeV electron-wiggler-generated hard x-ray ID17 beamline of the European Synchrotron Radiation Facility. Its pair of 125 parallel, 8 mm deep, 0.100 mm wide radiolucent slits, 0.400 mm on center, are perfused with nitrogen gas [N2] to dissipate heat during irradiation. Major improvements in uniformity of microbeam widths and good peak/valley dose ratios combined with a very high dose rate in targeted tissues have been achieved.
Articolo in rivista - Articolo scientifico
tungsten collimator, microbeams, MRT
English
2005
76
6
064303
reserved
Brauer-Krisch, E., Bravin, A., Zhang, L., Siegbahn, E., Stepanek, J., Blattmann, H., et al. (2005). Characterization of a tungsten/gas multislit collimator for microbeam radiation therapy at the European Synchrotron Radiation Facility. REVIEW OF SCIENTIFIC INSTRUMENTS, 76(6) [10.1063/1.1915270].
File in questo prodotto:
File Dimensione Formato  
brauer-msc-revsciinst.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 514.22 kB
Formato Adobe PDF
514.22 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/342945
Citazioni
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 41
Social impact