Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.
Cabrera, A., Abusleme, A., dos Anjos, J., Bezerra, T., Bongrand, M., Bourgeois, C., et al. (2021). Neutrino physics with an opaque detector. COMMUNICATIONS PHYSICS, 4(1) [10.1038/s42005-021-00763-5].
Neutrino physics with an opaque detector
Cabrera, A.
;Abusleme, A.;dos Anjos, J.;Bezerra, T. J. C.;Bongrand, M.;Bourgeois, C.;Breton, D.;Buck, C.;Busto, J.;Calvo, E.;Chauveau, E.;Chen, M.;Chimenti, P.;Dal Corso, F.;De Conto, G.;Dusini, S.;Fiorentini, G.;Martins, C. Frigerio;Givaudan, A.;Govoni, P.;Gramlich, B.;Grassi, M.;Han, Y.;Hartnell, J.;Hugon, C.;Jiménez, S.;de Kerret, H.;Le Nevé, A.;Loaiza, P.;Maalmi, J.;Mantovani, F.;Manzanillas, L.;Marquet, C.;Martino, J.;Navas-Nicolás, D.;Nunokawa, H.;Obolensky, M.;Ochoa-Ricoux, J. P.;Ortona, G.;Palomares, C.;Pessina, F.;Pin, A.;Porter, J. C. C.;Pravikoff, M. S.;Roche, M.;Roskovec, B.;Roy, N.;Santos, C.;Schoppmann, S.;Serafini, A.;Simard, L.;Sisti, M.;Stanco, L.;Strati, V.;Stutzmann, J. -S.;Suekane, F.;Verdugo, A.;Viaud, B.;Volpe, C.;Vrignon, C.;Wagner, S.;Yermia, F.
2021
Abstract
In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.
Cabrera, A., Abusleme, A., dos Anjos, J., Bezerra, T., Bongrand, M., Bourgeois, C., et al. (2021). Neutrino physics with an opaque detector. COMMUNICATIONS PHYSICS, 4(1) [10.1038/s42005-021-00763-5].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/342559
Citazioni
7
6
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2021-2023 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.