One of the crucial tasks of pharmaceutical industry is to quantify the potential genotoxic impurities (PGIs) coming from the process of drug production. The European Medicines Agency (EMEA) imposes analytical testing limits in the order of g/g, depending on drug dosage and exposure period, that means the need of a sensitive and selective method of analysis. Liquid chromatography coupled to electrospray ionization mass spectrometry (LC–ESI-MS) has been demonstrated as the most versatile approach to detect PGIs in complex matrices. However, time consuming derivatization processes are needed to enhance sensitivity and selectivity, and to overcome matrix effects (ME) that may arise from active pharmaceutical ingredients (APIs) or excipients. We propose the use of the Direct-EI LC–MS as an alternative approach to detect and quantify PGIs in drug formulations. The Direct-EI LC–MS interface is based on electron ionization (EI) which is well suited for the detection of low molecular weight compounds of different polarity, without derivatization and with no sign of ME. The method has been successfully applied to the detection of PGIs belonging to the class of alkylation agents. Calibration experiments show satisfactory linearity and precision data. Recoveries in low enriched samples spanned from 55 to 82%, and were not affected by ME. The method limits of detection (LODs), varying from 0.13 to 1.5 g/g, were satisfactory for the quantitation of the target PGIs at the level required by regulatory agencies.

Cappiello, A., Famiglini, G., Palma, P., Termopoli, V., Trufelli, H. (2012). A new liquid chromatography–mass spectrometry approach for generic screening and quantitation of potential genotoxic alkylation compounds without derivatization. JOURNAL OF CHROMATOGRAPHY A, 1255, 286-290 [10.1016/j.chroma.2011.12.068].

A new liquid chromatography–mass spectrometry approach for generic screening and quantitation of potential genotoxic alkylation compounds without derivatization

Termopoli, V;
2012

Abstract

One of the crucial tasks of pharmaceutical industry is to quantify the potential genotoxic impurities (PGIs) coming from the process of drug production. The European Medicines Agency (EMEA) imposes analytical testing limits in the order of g/g, depending on drug dosage and exposure period, that means the need of a sensitive and selective method of analysis. Liquid chromatography coupled to electrospray ionization mass spectrometry (LC–ESI-MS) has been demonstrated as the most versatile approach to detect PGIs in complex matrices. However, time consuming derivatization processes are needed to enhance sensitivity and selectivity, and to overcome matrix effects (ME) that may arise from active pharmaceutical ingredients (APIs) or excipients. We propose the use of the Direct-EI LC–MS as an alternative approach to detect and quantify PGIs in drug formulations. The Direct-EI LC–MS interface is based on electron ionization (EI) which is well suited for the detection of low molecular weight compounds of different polarity, without derivatization and with no sign of ME. The method has been successfully applied to the detection of PGIs belonging to the class of alkylation agents. Calibration experiments show satisfactory linearity and precision data. Recoveries in low enriched samples spanned from 55 to 82%, and were not affected by ME. The method limits of detection (LODs), varying from 0.13 to 1.5 g/g, were satisfactory for the quantitation of the target PGIs at the level required by regulatory agencies.
Articolo in rivista - Articolo scientifico
Genotoxic impurities, Pharmaceutical formulation, Underivatized alkylating agents, LC–MS, Direct-EI interface
English
27-dic-2011
2012
1255
286
290
reserved
Cappiello, A., Famiglini, G., Palma, P., Termopoli, V., Trufelli, H. (2012). A new liquid chromatography–mass spectrometry approach for generic screening and quantitation of potential genotoxic alkylation compounds without derivatization. JOURNAL OF CHROMATOGRAPHY A, 1255, 286-290 [10.1016/j.chroma.2011.12.068].
File in questo prodotto:
File Dimensione Formato  
53(2012).pdf

Solo gestori archivio

Dimensione 415.8 kB
Formato Adobe PDF
415.8 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/331284
Citazioni