A new method for the direct ESR detection of free radicals in rat myocardial tissue is described. Isolated rat atria are continuously monitored for heart rate and contractile force; at the end of the experimental period the beating organs are inserted into quartz ESR tubes and immediately frozen in liquid nitrogen. Spectra obtained from these preparations show the presence of very weak radical signals. When ESR spectra are recorded on samples obtained from pools of rat atria pulverized under liquid nitrogen, the radical lines are markedly stronger than those observed for intact organs: contaminating metals are also frequently detected. These findings indicate that crushing or grinding procedures carried out under liquid nitrogen produce artifactual ESR active species. The new method described in the present paper does not involve mechanical interventions and therefore should yield reliable artifact-free results. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.

Monti, E., Morazzoni, F., Perletti, G., Piccinini, F. (1990). A NEW APPROACH TO THE DIRECT DETECTION OF FREE-RADICALS IN THE INTACT MYOCARDIUM. FREE RADICAL RESEARCH COMMUNICATIONS, 8(3), 161-166 [10.3109/10715769009087989].

A NEW APPROACH TO THE DIRECT DETECTION OF FREE-RADICALS IN THE INTACT MYOCARDIUM

MORAZZONI, FRANCA;
1990

Abstract

A new method for the direct ESR detection of free radicals in rat myocardial tissue is described. Isolated rat atria are continuously monitored for heart rate and contractile force; at the end of the experimental period the beating organs are inserted into quartz ESR tubes and immediately frozen in liquid nitrogen. Spectra obtained from these preparations show the presence of very weak radical signals. When ESR spectra are recorded on samples obtained from pools of rat atria pulverized under liquid nitrogen, the radical lines are markedly stronger than those observed for intact organs: contaminating metals are also frequently detected. These findings indicate that crushing or grinding procedures carried out under liquid nitrogen produce artifactual ESR active species. The new method described in the present paper does not involve mechanical interventions and therefore should yield reliable artifact-free results. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
Articolo in rivista - Articolo scientifico
free radicals, EPR,
English
1990
8
3
161
166
none
Monti, E., Morazzoni, F., Perletti, G., Piccinini, F. (1990). A NEW APPROACH TO THE DIRECT DETECTION OF FREE-RADICALS IN THE INTACT MYOCARDIUM. FREE RADICAL RESEARCH COMMUNICATIONS, 8(3), 161-166 [10.3109/10715769009087989].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/32236
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
Social impact