Background—Heart failure patients with implantable cardioverter-defibrillators (ICDs) or an ICD for resynchronization therapy often visit the hospital for unscheduled examinations, placing a great burden on healthcare providers. We hypothesized that Internet-based remote interrogation systems could reduce emergency healthcare visits. Methods and Results—This multicenter randomized trial involving 200 patients compared remote monitoring with standard patient management consisting of scheduled visits and patient response to audible ICD alerts. The primary end point was the rate of emergency department or urgent in-office visits for heart failure, arrhythmias, or ICD-related events. Over 16 months, such visits were 35% less frequent in the remote arm (75 versus 117; incidence density, 0.59 versus 0.93 events per year; P 0.005). A 21% difference was observed in the rates of total healthcare visits for heart failure, arrhythmias, or ICD-related events (4.40 versus 5.74 events per year; P 0.001). The time from an ICD alert condition to review of the data was reduced from 24.8 days in the standard arm to 1.4 days in the remote arm (P 0.001). The patients’ clinical status, as measured by the Clinical Composite Score, was similar in the 2 groups, whereas a more favorable change in quality of life (Minnesota Living With Heart Failure Questionnaire) was observed from the baseline to the 16th month in the remote arm (P 0.026). Conclusions—Remote monitoring reduces emergency department/urgent in-office visits and, in general, total healthcare use in patients with ICD or defibrillators for resynchronization therapy. Compared with standard follow-up through in-office visits and audible ICD alerts, remote monitoring results in increased efficiency for healthcare providers and improved quality of care for patients.

Landolina, M., Perego, G., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., et al. (2012). Remote monitoring reduces healthcare utilization and improbe quality of care in heart failure patients with implantable defribillators: the EVOLVO (Evolution of Management Strategies of Heart Failure Patients with Implantable Defribillators) Study. CIRCULATION, 125, 2985-2992 [10.1161/CIRCULATIONAHA.111.088971].

Remote monitoring reduces healthcare utilization and improbe quality of care in heart failure patients with implantable defribillators: the EVOLVO (Evolution of Management Strategies of Heart Failure Patients with Implantable Defribillators) Study

PARATI, GIANFRANCO;
2012

Abstract

Background—Heart failure patients with implantable cardioverter-defibrillators (ICDs) or an ICD for resynchronization therapy often visit the hospital for unscheduled examinations, placing a great burden on healthcare providers. We hypothesized that Internet-based remote interrogation systems could reduce emergency healthcare visits. Methods and Results—This multicenter randomized trial involving 200 patients compared remote monitoring with standard patient management consisting of scheduled visits and patient response to audible ICD alerts. The primary end point was the rate of emergency department or urgent in-office visits for heart failure, arrhythmias, or ICD-related events. Over 16 months, such visits were 35% less frequent in the remote arm (75 versus 117; incidence density, 0.59 versus 0.93 events per year; P 0.005). A 21% difference was observed in the rates of total healthcare visits for heart failure, arrhythmias, or ICD-related events (4.40 versus 5.74 events per year; P 0.001). The time from an ICD alert condition to review of the data was reduced from 24.8 days in the standard arm to 1.4 days in the remote arm (P 0.001). The patients’ clinical status, as measured by the Clinical Composite Score, was similar in the 2 groups, whereas a more favorable change in quality of life (Minnesota Living With Heart Failure Questionnaire) was observed from the baseline to the 16th month in the remote arm (P 0.026). Conclusions—Remote monitoring reduces emergency department/urgent in-office visits and, in general, total healthcare use in patients with ICD or defibrillators for resynchronization therapy. Compared with standard follow-up through in-office visits and audible ICD alerts, remote monitoring results in increased efficiency for healthcare providers and improved quality of care for patients.
Articolo in rivista - Articolo scientifico
cardiac resynchronization therapy defibrillators, implantable heart failure telemedicine
English
2012
125
2985
2992
reserved
Landolina, M., Perego, G., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., et al. (2012). Remote monitoring reduces healthcare utilization and improbe quality of care in heart failure patients with implantable defribillators: the EVOLVO (Evolution of Management Strategies of Heart Failure Patients with Implantable Defribillators) Study. CIRCULATION, 125, 2985-2992 [10.1161/CIRCULATIONAHA.111.088971].
File in questo prodotto:
File Dimensione Formato  
Remote monitoring-Circulation 2012.pdf

Solo gestori archivio

Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/32187
Citazioni
  • Scopus 280
  • ???jsp.display-item.citation.isi??? 241
Social impact