Patients with sepsis have typically reduced concentrations of hemoglobin and albumin, the major components of noncarbonic buffer power (b ). This could expose patients to high pH variations during acid-base disorders. The objective of this study is to compare, in vitro, noncarbonic b of patients with sepsis with that of healthy volunteers, and evaluate its distinct components. Whole blood and isolated plasma of 18 patients with sepsis and 18 controls were equilibrated with different CO2 mixtures. Blood gases, pH, and electrolytes were measured. Noncarbonic b and noncarbonic b due to variations in strong ion difference (b SID) were calculated for whole blood. Noncarbonic b and noncarbonic b normalized for albumin concentrations (b NORM) were calculated for isolated plasma. Representative values at pH = 7.40 were compared. Albumin proteoforms were evaluated via two-dimensional electrophoresis. Hemoglobin and albumin concentrations were significantly lower in patients with sepsis. Patients with sepsis had lower noncarbonic b both of whole blood (22.0 ± 1.9 vs. 31.6 ± 2.1 mmol/L, P < 0.01) and plasma (0.5 ± 1.0 vs. 3.7 ± 0.8 mmol/L, P < 0.01). Noncarbonic b SID was lower in patients (16.8 ± 1.9 vs. 24.4 ± 1.9 mmol/L, P < 0.01) and strongly correlated with hemoglobin concentration (r = 0.94, P < 0.01). Noncarbonic b NORM was lower in patients [0.01 (-0.01 to 0.04) vs. 0.08 (0.06–0.09) mmol/g, P < 0.01]. Patients with sepsis and controls showed different amounts of albumin proteoforms. Patients with sepsis are exposed to higher pH variations for any given change in CO2 due to lower concentrations of noncarbonic buffers and, possibly, an altered buffering function of albumin. In both patients with sepsis and healthy controls, electrolyte shifts are the major buffering mechanism during respiratory acid-base disorders. NEW & NOTEWORTHY Patients with sepsis are poorly protected against acute respiratory acid-base derangements due to a lower noncarbonic buffer power, which is caused both by a reduction in the major noncarbonic buffers, i.e. hemoglobin and albumin, and by a reduced buffering capacity of albumin. Electrolyte shifts from and to the red blood cells determining acute variations in strong ion difference are the major buffering mechanism during acute respiratory acid-base disorders.

Langer, T., Brusatori, S., Carlesso, E., Zadek, F., Brambilla, P., Ferraris Fusarini, C., et al. (2021). Low non-carbonic buffer power amplifies acute respiratory acid-base disorders in septic patients: an in-vitro study. JOURNAL OF APPLIED PHYSIOLOGY, 131(2), 464-473 [10.1152/japplphysiol.00787.2020].

Low non-carbonic buffer power amplifies acute respiratory acid-base disorders in septic patients: an in-vitro study

Langer, Thomas
Primo
;
Zadek, Francesco;Zanella, Alberto;Pesenti, Antonio;Grasselli, Giacomo
Ultimo
2021

Abstract

Patients with sepsis have typically reduced concentrations of hemoglobin and albumin, the major components of noncarbonic buffer power (b ). This could expose patients to high pH variations during acid-base disorders. The objective of this study is to compare, in vitro, noncarbonic b of patients with sepsis with that of healthy volunteers, and evaluate its distinct components. Whole blood and isolated plasma of 18 patients with sepsis and 18 controls were equilibrated with different CO2 mixtures. Blood gases, pH, and electrolytes were measured. Noncarbonic b and noncarbonic b due to variations in strong ion difference (b SID) were calculated for whole blood. Noncarbonic b and noncarbonic b normalized for albumin concentrations (b NORM) were calculated for isolated plasma. Representative values at pH = 7.40 were compared. Albumin proteoforms were evaluated via two-dimensional electrophoresis. Hemoglobin and albumin concentrations were significantly lower in patients with sepsis. Patients with sepsis had lower noncarbonic b both of whole blood (22.0 ± 1.9 vs. 31.6 ± 2.1 mmol/L, P < 0.01) and plasma (0.5 ± 1.0 vs. 3.7 ± 0.8 mmol/L, P < 0.01). Noncarbonic b SID was lower in patients (16.8 ± 1.9 vs. 24.4 ± 1.9 mmol/L, P < 0.01) and strongly correlated with hemoglobin concentration (r = 0.94, P < 0.01). Noncarbonic b NORM was lower in patients [0.01 (-0.01 to 0.04) vs. 0.08 (0.06–0.09) mmol/g, P < 0.01]. Patients with sepsis and controls showed different amounts of albumin proteoforms. Patients with sepsis are exposed to higher pH variations for any given change in CO2 due to lower concentrations of noncarbonic buffers and, possibly, an altered buffering function of albumin. In both patients with sepsis and healthy controls, electrolyte shifts are the major buffering mechanism during respiratory acid-base disorders. NEW & NOTEWORTHY Patients with sepsis are poorly protected against acute respiratory acid-base derangements due to a lower noncarbonic buffer power, which is caused both by a reduction in the major noncarbonic buffers, i.e. hemoglobin and albumin, and by a reduced buffering capacity of albumin. Electrolyte shifts from and to the red blood cells determining acute variations in strong ion difference are the major buffering mechanism during acute respiratory acid-base disorders.
Articolo in rivista - Articolo scientifico
Acid-base equilibrium; Acidosis; Buffers; Electrolytes; Respiratory; Sepsis;
English
17-giu-2021
2021
131
2
464
473
none
Langer, T., Brusatori, S., Carlesso, E., Zadek, F., Brambilla, P., Ferraris Fusarini, C., et al. (2021). Low non-carbonic buffer power amplifies acute respiratory acid-base disorders in septic patients: an in-vitro study. JOURNAL OF APPLIED PHYSIOLOGY, 131(2), 464-473 [10.1152/japplphysiol.00787.2020].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/317466
Citazioni
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 16
Social impact