Background: Modern high-spatial-resolution radiologic methods enable increasingly detailed volumetric postmortem investigations of human neuroanatomy for diagnostic, research, and educational purposes. Purpose: To evaluate the viability of postmortem x-ray phase-contrast micro-CT to provide tissue-conserving, high-spatial-resolution, three-dimensional neuroimaging of the human spinal cord and column by comparing quality of x-ray phase-contrast microCT images of nondissected Thiel-embalmed human spines with images of extracted formalin-fixed human spinal cords. Specific focus was placed on assessing the detection of micrometric spinal cord soft-tissue structure and vasculature. Materials and Methods: In this study from August 2015 to August 2019, three Thiel-embalmed human spinal column samples, unilaterally perfused with an iodinated vascular contrast agent, and three extracted formalin-fixed spinal cord samples were imaged postmortem at a synchrotron radiation facility. Propagation-based x-ray phase-contrast micro-CT was used with monochromatic 60-keV x-rays and a detector with either 46-µm or 8-µm pixel sizes. A single-distance phase-retrieval algorithm was applied to the acquired CT projection images in advance of filtered back projection CT reconstruction. The influence on image quality of Thiel versus formalin embalming was examined, and images were qualitatively evaluated in terms of the value of their anatomic representations. Results: The x-ray phase-contrast micro-CT of Thiel-embalmed samples resulted in soft-tissue contrast within the vertebral canal, despite evident nervous tissue deterioration after Thiel embalming. Gross spinal cord anatomy, spinal meninges, contrast agent-enhanced spinal vasculature, and spinal nerves were all well rendered alongside surrounding vertebral bone structure. The x-ray phase-contrast micro-CT of formalin-fixed boneless cords led to much higher gray versus white matter contrast and to microscale visualization of deep medullary vasculature and neuronal perikarya. Conclusion: This work demonstrated the use of x-ray phase-contrast micro-CT for detailed volumetric anatomic visualization of embalmed human spines. The method provided three-dimensional display of bone, nervous tissue, and vasculature at microscale resolutions without exogenous contrast agents.

Barbone, G., Bravin, A., Mittone, A., Grosu, S., Ricke, J., Cavaletti, G., et al. (2021). High-spatial-resolution three-dimensional imaging of human spinal cord and column anatomy with postmortem x-ray phase-contrast micro-CT. RADIOLOGY, 298(1), 135-146 [10.1148/RADIOL.2020201622].

High-spatial-resolution three-dimensional imaging of human spinal cord and column anatomy with postmortem x-ray phase-contrast micro-CT

Bravin A.;Cavaletti G.;
2021

Abstract

Background: Modern high-spatial-resolution radiologic methods enable increasingly detailed volumetric postmortem investigations of human neuroanatomy for diagnostic, research, and educational purposes. Purpose: To evaluate the viability of postmortem x-ray phase-contrast micro-CT to provide tissue-conserving, high-spatial-resolution, three-dimensional neuroimaging of the human spinal cord and column by comparing quality of x-ray phase-contrast microCT images of nondissected Thiel-embalmed human spines with images of extracted formalin-fixed human spinal cords. Specific focus was placed on assessing the detection of micrometric spinal cord soft-tissue structure and vasculature. Materials and Methods: In this study from August 2015 to August 2019, three Thiel-embalmed human spinal column samples, unilaterally perfused with an iodinated vascular contrast agent, and three extracted formalin-fixed spinal cord samples were imaged postmortem at a synchrotron radiation facility. Propagation-based x-ray phase-contrast micro-CT was used with monochromatic 60-keV x-rays and a detector with either 46-µm or 8-µm pixel sizes. A single-distance phase-retrieval algorithm was applied to the acquired CT projection images in advance of filtered back projection CT reconstruction. The influence on image quality of Thiel versus formalin embalming was examined, and images were qualitatively evaluated in terms of the value of their anatomic representations. Results: The x-ray phase-contrast micro-CT of Thiel-embalmed samples resulted in soft-tissue contrast within the vertebral canal, despite evident nervous tissue deterioration after Thiel embalming. Gross spinal cord anatomy, spinal meninges, contrast agent-enhanced spinal vasculature, and spinal nerves were all well rendered alongside surrounding vertebral bone structure. The x-ray phase-contrast micro-CT of formalin-fixed boneless cords led to much higher gray versus white matter contrast and to microscale visualization of deep medullary vasculature and neuronal perikarya. Conclusion: This work demonstrated the use of x-ray phase-contrast micro-CT for detailed volumetric anatomic visualization of embalmed human spines. The method provided three-dimensional display of bone, nervous tissue, and vasculature at microscale resolutions without exogenous contrast agents.
Articolo in rivista - Articolo scientifico
high-spatial-resolution, CT scan, spinal cord, phase-contrast
English
27-ott-2020
2021
298
1
135
146
reserved
Barbone, G., Bravin, A., Mittone, A., Grosu, S., Ricke, J., Cavaletti, G., et al. (2021). High-spatial-resolution three-dimensional imaging of human spinal cord and column anatomy with postmortem x-ray phase-contrast micro-CT. RADIOLOGY, 298(1), 135-146 [10.1148/RADIOL.2020201622].
File in questo prodotto:
File Dimensione Formato  
Barbone-2021-Radiology-Suppl Mat-VoR.pdf

Solo gestori archivio

Descrizione: Supplementary material
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 148.06 kB
Formato Adobe PDF
148.06 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Barbone-2021-Radiology-VoR.pdf

Solo gestori archivio

Descrizione: Original Research Article
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 10.7 MB
Formato Adobe PDF
10.7 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/300828
Citazioni
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 25
Social impact