Transvaginal sonographically guided puncture may be used for diagnostic and therapeutic purpose in general gynecology and in oncology. To define the complication rate of this technique, 500 consecutive procedures were reviewed; 289 procedures were on cystic masses, 146 on solid tumors, 34 on mixed tumors, and 31 on other lesions. No life-threatening complications occurred. Early mild and self-limited complications developed in eight procedures (1.6%). Short-term complications occurred in four cases (0.8%; two infections, one pelvic pain, one hemorrhage); two of these required surgery. Transvaginal sonographically guided puncture is safe and does not entail a higher risk of infection than transabdominal punctures.

Zanetta, G., Lissoni, A., Franchi, D., Pittelli, M., Cormio, G., Trio, D. (1996). Safety of transvaginal fine needle puncture of gynecologic masses: a report after 500 consecutive procedures. JOURNAL OF ULTRASOUND IN MEDICINE, 15(5), 401-404 [10.7863/jum.1996.15.5.401].

Safety of transvaginal fine needle puncture of gynecologic masses: a report after 500 consecutive procedures

LISSONI, ANDREA ALBERTO;
1996

Abstract

Transvaginal sonographically guided puncture may be used for diagnostic and therapeutic purpose in general gynecology and in oncology. To define the complication rate of this technique, 500 consecutive procedures were reviewed; 289 procedures were on cystic masses, 146 on solid tumors, 34 on mixed tumors, and 31 on other lesions. No life-threatening complications occurred. Early mild and self-limited complications developed in eight procedures (1.6%). Short-term complications occurred in four cases (0.8%; two infections, one pelvic pain, one hemorrhage); two of these required surgery. Transvaginal sonographically guided puncture is safe and does not entail a higher risk of infection than transabdominal punctures.
Articolo in rivista - Articolo scientifico
Aged, 80 and over; Adolescent; Retrospective Studies; Middle Aged; Genital Diseases, Female; Female; Aged; Genital Neoplasms, Female; Adult; Humans; Biopsy, Needle
English
mag-1996
15
5
401
404
none
Zanetta, G., Lissoni, A., Franchi, D., Pittelli, M., Cormio, G., Trio, D. (1996). Safety of transvaginal fine needle puncture of gynecologic masses: a report after 500 consecutive procedures. JOURNAL OF ULTRASOUND IN MEDICINE, 15(5), 401-404 [10.7863/jum.1996.15.5.401].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/30059
Citazioni
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 5
Social impact