The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at the CMS experiment. Based on these results, the collaboration has chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.

Adam, W., Bergauer, T., Brondolin, E., Dragicevic, M., Friedl, M., Fruhwirth, R., et al. (2017). P-Type Silicon Strip Sensors for the new CMS Tracker at HL-LHC. JOURNAL OF INSTRUMENTATION, 12(6) [10.1088/1748-0221/12/06/P06018].

P-Type Silicon Strip Sensors for the new CMS Tracker at HL-LHC

Dinardo M. E.;
2017

Abstract

The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at the CMS experiment. Based on these results, the collaboration has chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.
Articolo in rivista - Articolo scientifico
Detector modelling and simulations II (electric fields, charge transport, multiplication and induction, pulse formation, electron emission, etc); Particle tracking detectors (Solid-state detectors); Radiation-hard detectors
English
2017
12
6
P06018
none
Adam, W., Bergauer, T., Brondolin, E., Dragicevic, M., Friedl, M., Fruhwirth, R., et al. (2017). P-Type Silicon Strip Sensors for the new CMS Tracker at HL-LHC. JOURNAL OF INSTRUMENTATION, 12(6) [10.1088/1748-0221/12/06/P06018].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/286476
Citazioni
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 18
Social impact