Neutrino fluxes are currently affected by large normalization uncertainties (5-10%). Neutrino physics will require measurements of absolute neutrino cross sections at the GeV scale with exquisite (1%) precision in the near future. For this reason a reduction of the present uncertainties by one order of magnitude would be highly beneficial. This goal might be achieved by producing a sign and momentum selected narrow band beam and monitoring the production of e+ in the decay tunnel from the decays of charged Kaons (Ke3 channel). This technique, which requires a special instrumented beam-line, would allow a 1% level measurement of the cross-sections of the neutrino species (νe and ν¯e) which are the final states involved in the searches for CP violation with muon neutrino beams at long-baseline. The ENUBET Horizon-2020 ERC Consolidator Grant, approved by the European Research Council in 2015, is the framework within which such a non conventional beam-line will be developed. We present a progress report of the project (2016-2021) after about one year of work, the experimental results on ultra-compact calorimeters suited for the instrumenting the decay tunnel and the R&D in the design of the hadronic beamline.

Longhin, A., Ballerini, G., Berra, A., Boanta, R., Bonesini, M., Brizzolari, C., et al. (2017). High precision measurements of neutrino fluxes with ENUBET. Intervento presentato a: XVII International Workshop on Neutrino Telescopes (NEUTEL2017), Venezia, Italy [10.22323/1.307.0050].

High precision measurements of neutrino fluxes with ENUBET

M. Bonesini;C. Brizzolari;G Brunetti;M. Tenti;F. Terranova;
2017

Abstract

Neutrino fluxes are currently affected by large normalization uncertainties (5-10%). Neutrino physics will require measurements of absolute neutrino cross sections at the GeV scale with exquisite (1%) precision in the near future. For this reason a reduction of the present uncertainties by one order of magnitude would be highly beneficial. This goal might be achieved by producing a sign and momentum selected narrow band beam and monitoring the production of e+ in the decay tunnel from the decays of charged Kaons (Ke3 channel). This technique, which requires a special instrumented beam-line, would allow a 1% level measurement of the cross-sections of the neutrino species (νe and ν¯e) which are the final states involved in the searches for CP violation with muon neutrino beams at long-baseline. The ENUBET Horizon-2020 ERC Consolidator Grant, approved by the European Research Council in 2015, is the framework within which such a non conventional beam-line will be developed. We present a progress report of the project (2016-2021) after about one year of work, the experimental results on ultra-compact calorimeters suited for the instrumenting the decay tunnel and the R&D in the design of the hadronic beamline.
paper
neutrino, neutrino fluxes, ENUBET
English
XVII International Workshop on Neutrino Telescopes (NEUTEL2017)
2017
2017
open
Longhin, A., Ballerini, G., Berra, A., Boanta, R., Bonesini, M., Brizzolari, C., et al. (2017). High precision measurements of neutrino fluxes with ENUBET. Intervento presentato a: XVII International Workshop on Neutrino Telescopes (NEUTEL2017), Venezia, Italy [10.22323/1.307.0050].
File in questo prodotto:
File Dimensione Formato  
10281-283999.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 8.69 MB
Formato Adobe PDF
8.69 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/283999
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
Social impact