The back-illuminated charge coupled devices (CCD) are suitable for soft X-ray photon detection. Their nominal performances suggest that they can boost both efficiency and resolving power of X-ray spectrometers based on diffraction gratings and two-dimensional position sensitive detectors. We tested the performances of two commercially available CCDs, intended to replace a more traditional microchannel plate (MCP) detector. Our tests show that the devices have excellent performances in terms of dark current, response linearity, detection efficiency and spatial resolution. We observed that the CCDs have better efficiency (more than 10 times) and better resolution (∼3 times) than the MCP. Moreover we found an intrinsic limit for the spatial resolution, which is almost independent of the detector pixel size and is estimated around 25 μm. © 2006 Elsevier B.V. All rights reserved.

Dinardo, M., Piazzalunga, A., Braicovich, L., Bisogni, V., Dallera, C., Giarda, K., et al. (2007). Gaining efficiency and resolution in soft X-ray emission spectrometers thanks to directly illuminated CCD detectors. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 570(1), 176-181 [10.1016/j.nima.2006.10.024].

Gaining efficiency and resolution in soft X-ray emission spectrometers thanks to directly illuminated CCD detectors

Dinardo M. E.
Primo
Membro del Collaboration Group
;
Piazzalunga A.
Membro del Collaboration Group
;
Tagliaferri A.
Membro del Collaboration Group
;
2007

Abstract

The back-illuminated charge coupled devices (CCD) are suitable for soft X-ray photon detection. Their nominal performances suggest that they can boost both efficiency and resolving power of X-ray spectrometers based on diffraction gratings and two-dimensional position sensitive detectors. We tested the performances of two commercially available CCDs, intended to replace a more traditional microchannel plate (MCP) detector. Our tests show that the devices have excellent performances in terms of dark current, response linearity, detection efficiency and spatial resolution. We observed that the CCDs have better efficiency (more than 10 times) and better resolution (∼3 times) than the MCP. Moreover we found an intrinsic limit for the spatial resolution, which is almost independent of the detector pixel size and is estimated around 25 μm. © 2006 Elsevier B.V. All rights reserved.
Articolo in rivista - Articolo scientifico
CCD detector, X-ray emission spectroscopy, X-ray spectrometer,
English
2007
570
1
176
181
none
Dinardo, M., Piazzalunga, A., Braicovich, L., Bisogni, V., Dallera, C., Giarda, K., et al. (2007). Gaining efficiency and resolution in soft X-ray emission spectrometers thanks to directly illuminated CCD detectors. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 570(1), 176-181 [10.1016/j.nima.2006.10.024].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/281606
Citazioni
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 26
Social impact