The ICARUS T600 detector is the largest liquid argon time projection chamber (LArTPC) to be built and operated [1]. This detector was in operation in the INFN Gran Sasso underground laboratory until 2012, exposed to the CERN Neutrino to Gran Sasso (CNGS) νμ beam, performing neutrino oscillation studies. The ICARUS T600 is presently under refurbishment in order to make it suitable for surface level operation, as it will serve as the far detector for the Short-Baseline Neutrino (SBN) Program at Fermilab [2]. A major upgrade of the ICARUS detector in order to allow it to cope with a high cosmic background is the upgrade of the light collection system. The study presented here shows a simulation to optimize the PMT layout to allow for the localization and identification of interaction within the T600. An excellent performance can be obtained, with an error on the localization smaller than 20 cm and of the order of a few percent in the identification of cosmic rays.

Falcone, A. (2017). Performance study of the new light collection system for the ICARUS T600 detector. JOURNAL OF PHYSICS. CONFERENCE SERIES, 888(1) [10.1088/1742-6596/888/1/012093].

Performance study of the new light collection system for the ICARUS T600 detector

Falcone, A
2017

Abstract

The ICARUS T600 detector is the largest liquid argon time projection chamber (LArTPC) to be built and operated [1]. This detector was in operation in the INFN Gran Sasso underground laboratory until 2012, exposed to the CERN Neutrino to Gran Sasso (CNGS) νμ beam, performing neutrino oscillation studies. The ICARUS T600 is presently under refurbishment in order to make it suitable for surface level operation, as it will serve as the far detector for the Short-Baseline Neutrino (SBN) Program at Fermilab [2]. A major upgrade of the ICARUS detector in order to allow it to cope with a high cosmic background is the upgrade of the light collection system. The study presented here shows a simulation to optimize the PMT layout to allow for the localization and identification of interaction within the T600. An excellent performance can be obtained, with an error on the localization smaller than 20 cm and of the order of a few percent in the identification of cosmic rays.
Articolo in rivista - Articolo scientifico
LAr TPC, neutrino
English
2017
888
1
012093
open
Falcone, A. (2017). Performance study of the new light collection system for the ICARUS T600 detector. JOURNAL OF PHYSICS. CONFERENCE SERIES, 888(1) [10.1088/1742-6596/888/1/012093].
File in questo prodotto:
File Dimensione Formato  
Articolo3.pdf

accesso aperto

Dimensione 442.02 kB
Formato Adobe PDF
442.02 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/276025
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
Social impact