Background: The most appropriate endo-therapeutic approach to biliary anastomotic strictures is yet to be defined. Aim: To retrospectively report on the endo-therapy of duct-to-duct anastomotic strictures during 2013 in Italy. Methods: Data were collected from 16 Endoscopy Units at the Italian Liver Transplantation Centers (BASALT study group). Results: Complete endo-therapy and follow-up data are available for 181 patients: 101 treated with plastic multistenting, 26 with fully covered self-expandable metal stenting and 54 with single stenting. Radiological success was achieved for 145 patients (80%), that is, 88% of plastic multistenting, 88% of self-expandable metal stenting and 61% of single stenting (P < 0.001 vs plastic multistenting; P < 0.05 vs self-expandable metal stenting). After first-line endo-therapy failure, the patients underwent a second-line endo-therapy with plastic multistenting for 25%, fully covered self-expandable metal stenting for 53% and single stenting for 22% of cases, and radiological success was achieved for 84%, that is, 100%, 85% and 63% with plastic multistenting, self-expandable metal stenting and single stenting (P < 0.05 vs plastic multistenting or self-expandable metal stenting) respectively. Procedure-related complications occurred in 7.8% of endoscopic retrograde cholangiopancreatographies. Overall, clinical success was achieved in 87% of patients after a median follow-up of 25 months. Conclusion: Plastic multistenting is confirmed as the preferred first-line treatment, while fully covered self-expandable metal stenting as rescue option for biliary anastomotic strictures. Single stenting has sub-optimal results and should be abandoned.

Cantu, P., Tarantino, I., Baldan, A., Mutignani, M., Tringali, A., Lombardi, G., et al. (2019). Endo-therapies for biliary duct-to-duct anastomotic stricture after liver transplantation: Outcomes of a nationwide survey. LIVER INTERNATIONAL, 39(7), 1355-1362 [10.1111/liv.14010].

Endo-therapies for biliary duct-to-duct anastomotic stricture after liver transplantation: Outcomes of a nationwide survey

De Carlis L.;
2019

Abstract

Background: The most appropriate endo-therapeutic approach to biliary anastomotic strictures is yet to be defined. Aim: To retrospectively report on the endo-therapy of duct-to-duct anastomotic strictures during 2013 in Italy. Methods: Data were collected from 16 Endoscopy Units at the Italian Liver Transplantation Centers (BASALT study group). Results: Complete endo-therapy and follow-up data are available for 181 patients: 101 treated with plastic multistenting, 26 with fully covered self-expandable metal stenting and 54 with single stenting. Radiological success was achieved for 145 patients (80%), that is, 88% of plastic multistenting, 88% of self-expandable metal stenting and 61% of single stenting (P < 0.001 vs plastic multistenting; P < 0.05 vs self-expandable metal stenting). After first-line endo-therapy failure, the patients underwent a second-line endo-therapy with plastic multistenting for 25%, fully covered self-expandable metal stenting for 53% and single stenting for 22% of cases, and radiological success was achieved for 84%, that is, 100%, 85% and 63% with plastic multistenting, self-expandable metal stenting and single stenting (P < 0.05 vs plastic multistenting or self-expandable metal stenting) respectively. Procedure-related complications occurred in 7.8% of endoscopic retrograde cholangiopancreatographies. Overall, clinical success was achieved in 87% of patients after a median follow-up of 25 months. Conclusion: Plastic multistenting is confirmed as the preferred first-line treatment, while fully covered self-expandable metal stenting as rescue option for biliary anastomotic strictures. Single stenting has sub-optimal results and should be abandoned.
Articolo in rivista - Articolo scientifico
biliary anastomotic stricture; ERCP; fully covered metal stenting; liver transplantation; plastic multistenting;
biliary anastomotic stricture; ERCP; fully covered metal stenting; liver transplantation; plastic multistenting
English
30-nov-2018
2019
39
7
1355
1362
none
Cantu, P., Tarantino, I., Baldan, A., Mutignani, M., Tringali, A., Lombardi, G., et al. (2019). Endo-therapies for biliary duct-to-duct anastomotic stricture after liver transplantation: Outcomes of a nationwide survey. LIVER INTERNATIONAL, 39(7), 1355-1362 [10.1111/liv.14010].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/275552
Citazioni
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 17
Social impact