Neutron Tomography (NT) is an established technique to non-destructively investigate the inner structure of a wide range of objects. The major drawback of NT is the long acquisition time required to perform a tomographic scan compared to an X-ray Computed Tomography (CT) scan, due to the limited particle flux of the existing neutron sources. Therefore, in the NT field there is great interest in the reduction of scan time, dictated by the high neutrons production cost, aimed at optimizing the beamtime use at neutron imaging beamlines. A way for decreasing the total scan time is to reduce the number of projections. Generally, iterative reconstruction methods have advantages over analytical algorithms, such as the widely used Filtered Back-Projection (FBP), when data are noisy and limited. This research is focused on the comparative analysis of different reconstruction techniques, aimed at finding the data processing procedure suitable for NT, that reduces the scan time without reduction of the reconstructed image quality. For this purpose, a phantom sample was analysed by means of a white beam NT performed at the IMAT beamline, ISIS Neutron Source, U.K . Experimental data were used to test the performances of the FBP algorithm and different iterative reconstruction methods as a function of the number of projections and for different setups of the imaging system. The reconstructed images were quantitatively compared in terms of image quality indexes and the benefits of iterative methods for the limited data problem are discussed.

Micieli, D., Minniti, T., Formoso, V., Kockelmann, W., Gorini, G. (2018). A comparative study of reconstruction methods applied to Neutron Tomography. JOURNAL OF INSTRUMENTATION, 13(6) [10.1088/1748-0221/13/06/C06006].

A comparative study of reconstruction methods applied to Neutron Tomography

Gorini G.
Ultimo
2018

Abstract

Neutron Tomography (NT) is an established technique to non-destructively investigate the inner structure of a wide range of objects. The major drawback of NT is the long acquisition time required to perform a tomographic scan compared to an X-ray Computed Tomography (CT) scan, due to the limited particle flux of the existing neutron sources. Therefore, in the NT field there is great interest in the reduction of scan time, dictated by the high neutrons production cost, aimed at optimizing the beamtime use at neutron imaging beamlines. A way for decreasing the total scan time is to reduce the number of projections. Generally, iterative reconstruction methods have advantages over analytical algorithms, such as the widely used Filtered Back-Projection (FBP), when data are noisy and limited. This research is focused on the comparative analysis of different reconstruction techniques, aimed at finding the data processing procedure suitable for NT, that reduces the scan time without reduction of the reconstructed image quality. For this purpose, a phantom sample was analysed by means of a white beam NT performed at the IMAT beamline, ISIS Neutron Source, U.K . Experimental data were used to test the performances of the FBP algorithm and different iterative reconstruction methods as a function of the number of projections and for different setups of the imaging system. The reconstructed images were quantitatively compared in terms of image quality indexes and the benefits of iterative methods for the limited data problem are discussed.
Articolo in rivista - Articolo scientifico
Computerized Tomography (CT) and Computed Radiography (CR); Data processing Methods; Inspection with neutrons;
Computerized Tomography (CT) and Computed Radiography (CR); Data processing Methods; Inspection with neutrons
English
2018
13
6
C06006
none
Micieli, D., Minniti, T., Formoso, V., Kockelmann, W., Gorini, G. (2018). A comparative study of reconstruction methods applied to Neutron Tomography. JOURNAL OF INSTRUMENTATION, 13(6) [10.1088/1748-0221/13/06/C06006].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/270871
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 10
Social impact