Since squamous cell carcinoma antigen (SCC-Ag) testing became commercially available on the Architect platform, the previously established method on the Abbott IMx platform has been progressively replaced. Aim of this work was to compare SCC-Ag values obtained with the 2 methods. Clinical and laboratory data of 188 patients for whom SCC-Ag determination was requested, were reviewed. IMx was used to determine the levels of SCC-Ag from June 2007 to May 2009, while the Architect system was used from June 2009 to April 2011. Only patients consistently diagnosed with no evidence of disease, for whom at least 2 determinations with each analyzer were available were used. Comparison of the results obtained with the 2 systems was then performed. Mean values for SCC-Ag were 0.56 ng/mL (Standard Error (SE): 0.08) with the IMx method, and 1.08 ng/mL (SE 0.10) with Architect (p<0.0001). False positive results were found in 4.8% of patients with the IMx method and in 9.5% of patients with Architect (p=0.049). The values of SCC-Ag determined on the Architect platform are higher than those obtained on the IMx, with a higher percentage of false positive results. © 2013 Wichtig Editore.

Sandri, M., Salvatici, M., Mauro, C., Radice, D., Lentati, P., Massaro, M., et al. (2013). Detection of squamous cell carcinoma antigen with two systems in the follow-up of patients with cervical cancer. THE INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 28(3), 313-317 [10.5301/JBM.5000031].

Detection of squamous cell carcinoma antigen with two systems in the follow-up of patients with cervical cancer

Landoni F.
2013

Abstract

Since squamous cell carcinoma antigen (SCC-Ag) testing became commercially available on the Architect platform, the previously established method on the Abbott IMx platform has been progressively replaced. Aim of this work was to compare SCC-Ag values obtained with the 2 methods. Clinical and laboratory data of 188 patients for whom SCC-Ag determination was requested, were reviewed. IMx was used to determine the levels of SCC-Ag from June 2007 to May 2009, while the Architect system was used from June 2009 to April 2011. Only patients consistently diagnosed with no evidence of disease, for whom at least 2 determinations with each analyzer were available were used. Comparison of the results obtained with the 2 systems was then performed. Mean values for SCC-Ag were 0.56 ng/mL (Standard Error (SE): 0.08) with the IMx method, and 1.08 ng/mL (SE 0.10) with Architect (p<0.0001). False positive results were found in 4.8% of patients with the IMx method and in 9.5% of patients with Architect (p=0.049). The values of SCC-Ag determined on the Architect platform are higher than those obtained on the IMx, with a higher percentage of false positive results. © 2013 Wichtig Editore.
Articolo in rivista - Articolo scientifico
Cervical cancer; Methods comparison; Squamous cell carcinoma antigen; Tumor markers;
Cervical cancer; Methods comparison; Squamous cell carcinoma antigen; Tumor markers; Antigens, Neoplasm; Biomarkers, Tumor; Carcinoma, Squamous Cell; Female; Follow-Up Studies; Humans; Male; Middle Aged; Prospective Studies; Serpins; Uterine Cervical Neoplasms
English
2013
28
3
313
317
none
Sandri, M., Salvatici, M., Mauro, C., Radice, D., Lentati, P., Massaro, M., et al. (2013). Detection of squamous cell carcinoma antigen with two systems in the follow-up of patients with cervical cancer. THE INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 28(3), 313-317 [10.5301/JBM.5000031].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/264490
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
Social impact