A preclinical insert for small animal simultaneous SPECT and MR imaging, in particular for imaging mouse brains, is presented. It consists of ten static magnetic resonance imaging (MRI)-compatible gamma cameras based on tiles of silicon photomultipliers readout by a multichannel ASIC and coupled to 5 cm x 5 cm CsI(Tl) scintillators and to an MRI-compatible multipinhole collimator. Calibration and image reconstruction algorithm are illustrated. Mutual compatibility is demonstrated along with imaging performance that is comparable with other non-MR micro-SPECT systems: 0.9 mm tomographic spatial resolution across a transverse field of view of 15.6 mm, 12% energy resolution (at 140 keV), and 1105 cps/MBq sensitivity. Experimental results with phantoms (glass capillaries of 290 mu m diameter and a mini Derenzo) are presented.

Carminati, M., Valtorta, S., Belloli, S., Moresco, R., Savi, A., Iadanza, A., et al. (2019). Validation and Performance Assessment of a Preclinical SiPM-Based SPECT/MRI Insert. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 3(4), 483-490 [10.1109/TRPMS.2019.2893377].

Validation and Performance Assessment of a Preclinical SiPM-Based SPECT/MRI Insert

Valtorta, S.;Moresco, R. M.;
2019

Abstract

A preclinical insert for small animal simultaneous SPECT and MR imaging, in particular for imaging mouse brains, is presented. It consists of ten static magnetic resonance imaging (MRI)-compatible gamma cameras based on tiles of silicon photomultipliers readout by a multichannel ASIC and coupled to 5 cm x 5 cm CsI(Tl) scintillators and to an MRI-compatible multipinhole collimator. Calibration and image reconstruction algorithm are illustrated. Mutual compatibility is demonstrated along with imaging performance that is comparable with other non-MR micro-SPECT systems: 0.9 mm tomographic spatial resolution across a transverse field of view of 15.6 mm, 12% energy resolution (at 140 keV), and 1105 cps/MBq sensitivity. Experimental results with phantoms (glass capillaries of 290 mu m diameter and a mini Derenzo) are presented.
Articolo in rivista - Articolo scientifico
Gamma camera; multimodal imaging; multipinhole collimator; silicon photomultipliers (SiPMs)
English
2019
3
4
483
490
none
Carminati, M., Valtorta, S., Belloli, S., Moresco, R., Savi, A., Iadanza, A., et al. (2019). Validation and Performance Assessment of a Preclinical SiPM-Based SPECT/MRI Insert. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 3(4), 483-490 [10.1109/TRPMS.2019.2893377].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/264385
Citazioni
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
Social impact