A retrospective review was conducted to evaluate the mid-termresults (8.5 years follow-up) of the Varsys ET STETM (Zimmer, Warsaw, Indiana, USA. From 1995 to 2000, 225 total hip arthroplasty (THA) were performed using this device. All patients were evaluated clinically by the Harris Hip Score, and radiographically. The Hip Score increased fron 54 preoperatively to 97 point postoperatively. The stem displayed a varus alignment between 5° and 10° in 17cases without any clinical consequences (HHS 96.8). We recorded one case of septic loosening and one case of aseptic loosening. The stability of the stem was radiographically evaluated according to Engh's criteria, confirming bone ongrowth in all other cases.

D'Angelo, F., Murena, L., Vulcano, E., Zatti, G., Cherubino, P. (2010). Seven to twelwe years results with Versys ET cementless stem. A retrisoective study of 225 cases. HIP INTERNATIONAL, 20(1), 81-86 [10.1177/112070001002000112].

Seven to twelwe years results with Versys ET cementless stem. A retrisoective study of 225 cases

ZATTI, GIOVANNI;
2010

Abstract

A retrospective review was conducted to evaluate the mid-termresults (8.5 years follow-up) of the Varsys ET STETM (Zimmer, Warsaw, Indiana, USA. From 1995 to 2000, 225 total hip arthroplasty (THA) were performed using this device. All patients were evaluated clinically by the Harris Hip Score, and radiographically. The Hip Score increased fron 54 preoperatively to 97 point postoperatively. The stem displayed a varus alignment between 5° and 10° in 17cases without any clinical consequences (HHS 96.8). We recorded one case of septic loosening and one case of aseptic loosening. The stability of the stem was radiographically evaluated according to Engh's criteria, confirming bone ongrowth in all other cases.
Articolo in rivista - Articolo scientifico
Cementless prosthesis; Hip arthroplasty; Straight stem; Titanium; Varus alignment;
English
2010
20
1
81
86
none
D'Angelo, F., Murena, L., Vulcano, E., Zatti, G., Cherubino, P. (2010). Seven to twelwe years results with Versys ET cementless stem. A retrisoective study of 225 cases. HIP INTERNATIONAL, 20(1), 81-86 [10.1177/112070001002000112].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/26260
Citazioni
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
Social impact