This paper presents a low noise amplifier for large arrays of silicon photomultipliers (SiPMs) operated in cryogenic environments, especially liquid argon (87 K) and liquid nitrogen (77 K) . The goal is for one amplifier to read out a total photosensitive surface of tens of cm2 while retaining the capability to resolve single photoelectron signals. Due to the large capacitance of SiPMs, typically a few nF per cm2, the main contributor to noise is the series (voltage) component. A silicon-germanium heterojunction bipolar transistor (HBT) was selected as the input device of the cryogenic amplifier, followed by a fully differential operational amplifier, operated in an unconventional feedback configuration. The input referred voltage noise of the circuit at 77 K is just below 0.4 nV/Hz white (above 100 kHz) and 1 nV/Hz at 10 kHz. The value of the base spreading resistance of the HBT at 77 K was determined from noise measurements at different bias currents. Power consumption of the full circuit is about 2.5 mW . The design gives the flexibility to optimally compensate the feedback loop for different values of the input capacitance, and obtain a gain-bandwidth product in the GHz range. The signal-to-noise ratio obtained in reading out SiPMs is discussed for the case of a 300 kHz low pass filter and compared with the upper limit that would derive from applying optimum filtering algorithms.

Carniti, P., Falcone, A., Gotti, C., Lucchini, A., Pessina, G., Riboldi, S., et al. (2020). A low noise and low power cryogenic amplifier for single photoelectron sensitivity with large arrays of SiPMs. JOURNAL OF INSTRUMENTATION, 15(1) [10.1088/1748-0221/15/01/P01008].

A low noise and low power cryogenic amplifier for single photoelectron sensitivity with large arrays of SiPMs

Carniti, P.;Falcone, A.;Gotti, C.
;
Pessina, G.;Terranova, F.
2020

Abstract

This paper presents a low noise amplifier for large arrays of silicon photomultipliers (SiPMs) operated in cryogenic environments, especially liquid argon (87 K) and liquid nitrogen (77 K) . The goal is for one amplifier to read out a total photosensitive surface of tens of cm2 while retaining the capability to resolve single photoelectron signals. Due to the large capacitance of SiPMs, typically a few nF per cm2, the main contributor to noise is the series (voltage) component. A silicon-germanium heterojunction bipolar transistor (HBT) was selected as the input device of the cryogenic amplifier, followed by a fully differential operational amplifier, operated in an unconventional feedback configuration. The input referred voltage noise of the circuit at 77 K is just below 0.4 nV/Hz white (above 100 kHz) and 1 nV/Hz at 10 kHz. The value of the base spreading resistance of the HBT at 77 K was determined from noise measurements at different bias currents. Power consumption of the full circuit is about 2.5 mW . The design gives the flexibility to optimally compensate the feedback loop for different values of the input capacitance, and obtain a gain-bandwidth product in the GHz range. The signal-to-noise ratio obtained in reading out SiPMs is discussed for the case of a 300 kHz low pass filter and compared with the upper limit that would derive from applying optimum filtering algorithms.
Articolo in rivista - Articolo scientifico
Analogue electronic circuits; Front-end electronics for detector readout; Noble liquid detectors (scintillation, ionization, double-phase); Photon detectors for UV, visible and IR photons (solid-state);
English
13-gen-2020
2020
15
1
P01008
none
Carniti, P., Falcone, A., Gotti, C., Lucchini, A., Pessina, G., Riboldi, S., et al. (2020). A low noise and low power cryogenic amplifier for single photoelectron sensitivity with large arrays of SiPMs. JOURNAL OF INSTRUMENTATION, 15(1) [10.1088/1748-0221/15/01/P01008].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/260140
Citazioni
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 8
Social impact