Extracorporeal life support (ECLS) is fast becoming more common place for use in adult patients failing mechanical ventilation. Management of coagulation and thrombosis has long been a major complication in the use of ECLS therapies. Scanning electron microscopy (SEM) of membrane oxygenators (MOs) after use in ECLS circuits can offer novel insight into any thrombotic material deposition on the MO. In this pilot study, we analyzed five explanted MOs immediately after use in a sheep model of different acute respiratory distress syndrome (ARDS). We describe our methods of MO dissection, sample preparation, image capture, and results. Of the five MOs analyzed, those that received continuous heparin infusion showed very little thrombosis formation or other clot material, whereas those that were used with only initial heparin bolus showed readily apparent thrombotic material.
Beely, B., Campbell, J., Meyer, A., Langer, T., Negaard, K., Chung, K., et al. (2016). Electron Microscopy as a Tool for Assessment of Anticoagulation Strategies during Extracorporeal Life Support: The Proof Is on the Membrane. ASAIO JOURNAL, 62(5), 525-532 [10.1097/MAT.0000000000000394].
Electron Microscopy as a Tool for Assessment of Anticoagulation Strategies during Extracorporeal Life Support: The Proof Is on the Membrane
Langer, T;
2016
Abstract
Extracorporeal life support (ECLS) is fast becoming more common place for use in adult patients failing mechanical ventilation. Management of coagulation and thrombosis has long been a major complication in the use of ECLS therapies. Scanning electron microscopy (SEM) of membrane oxygenators (MOs) after use in ECLS circuits can offer novel insight into any thrombotic material deposition on the MO. In this pilot study, we analyzed five explanted MOs immediately after use in a sheep model of different acute respiratory distress syndrome (ARDS). We describe our methods of MO dissection, sample preparation, image capture, and results. Of the five MOs analyzed, those that received continuous heparin infusion showed very little thrombosis formation or other clot material, whereas those that were used with only initial heparin bolus showed readily apparent thrombotic material.File | Dimensione | Formato | |
---|---|---|---|
Beely BM_ASAIO J_2016.pdf
Solo gestori archivio
Dimensione
681.83 kB
Formato
Adobe PDF
|
681.83 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.