The bacterial biofilm formation in the oral cavity and the microbial activity around the implant tissue represent a potential factor on the interface between bone and implant fixture that could induce an inflammatory phenomenon and generate an increased risk for mucositis and peri-implantitis. The aim of the present clinical trial was to investigate the bacterial quality of a new antibacterial coating of the internal chamber of the implant in vivo at six months. The PIXIT implant (Edierre srl, Genova Italy) is prepared by coating the implant with an alcoholic solution containing polysiloxane oligomers and chlorhexidine gluconate at 1%. A total of 15 healthy patients (60 implants) with non-contributory past medical history (nine women and six men, all non-smokers, mean age of 53 years, ranging from 45–61 years) were scheduled to receive bilateral fixed prostheses or crown restorations supported by an implant fixture. No adverse effects and no implant failure were reported at four months. All experimental sites showed a good soft tissue healing at the experimental point times and no local evidence of inflammation was observed. Real-Time Polymerase Chain Reaction (PCR) analysis on coated and uncoated implants showed a decrease of the bacterial count in the internal part of the implant chamber. The mean of total bacteria loading (TBL) detected in each PCR reaction was lower in treated implants (81,038 units/reaction) compared to untreated implants (90,057 units/reaction) (p < 0.01). The polymeric chlorhexydine coating of the internal chamber of the implant showed the ability to control the bacterial loading at the level of the peri-implant tissue. Moreover, the investigation demonstrated that the coating is able to influence also the quality of the microbiota, in particular on the species involved in the pathogenesis of peri-implantitis that are involved with a higher risk of long-term failure of the dental implant restoration.

Carinci, F., Lauritano, D., Bignozzi, C., Pazzi, D., Candotto, V., Santos de Oliveira, P., et al. (2019). A new strategy against peri-implantitis: Antibacterial internal coating. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 20(16) [10.3390/ijms20163897].

A new strategy against peri-implantitis: Antibacterial internal coating

Lauritano, Dorina
Co-primo
Membro del Collaboration Group
;
2019

Abstract

The bacterial biofilm formation in the oral cavity and the microbial activity around the implant tissue represent a potential factor on the interface between bone and implant fixture that could induce an inflammatory phenomenon and generate an increased risk for mucositis and peri-implantitis. The aim of the present clinical trial was to investigate the bacterial quality of a new antibacterial coating of the internal chamber of the implant in vivo at six months. The PIXIT implant (Edierre srl, Genova Italy) is prepared by coating the implant with an alcoholic solution containing polysiloxane oligomers and chlorhexidine gluconate at 1%. A total of 15 healthy patients (60 implants) with non-contributory past medical history (nine women and six men, all non-smokers, mean age of 53 years, ranging from 45–61 years) were scheduled to receive bilateral fixed prostheses or crown restorations supported by an implant fixture. No adverse effects and no implant failure were reported at four months. All experimental sites showed a good soft tissue healing at the experimental point times and no local evidence of inflammation was observed. Real-Time Polymerase Chain Reaction (PCR) analysis on coated and uncoated implants showed a decrease of the bacterial count in the internal part of the implant chamber. The mean of total bacteria loading (TBL) detected in each PCR reaction was lower in treated implants (81,038 units/reaction) compared to untreated implants (90,057 units/reaction) (p < 0.01). The polymeric chlorhexydine coating of the internal chamber of the implant showed the ability to control the bacterial loading at the level of the peri-implant tissue. Moreover, the investigation demonstrated that the coating is able to influence also the quality of the microbiota, in particular on the species involved in the pathogenesis of peri-implantitis that are involved with a higher risk of long-term failure of the dental implant restoration.
Articolo in rivista - Articolo scientifico
Bacterial loading; Chlorhexidine gluconate; Coating; Implant dentistry; Peri-implantitis;
bacterial loading; chlorhexidine gluconate; coating; implant dentistry; peri-implantitis
English
2019
20
16
3897
reserved
Carinci, F., Lauritano, D., Bignozzi, C., Pazzi, D., Candotto, V., Santos de Oliveira, P., et al. (2019). A new strategy against peri-implantitis: Antibacterial internal coating. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 20(16) [10.3390/ijms20163897].
File in questo prodotto:
File Dimensione Formato  
343 ijms-20-03897.pdf

Solo gestori archivio

Descrizione: Articolo principale
Tipologia di allegato: Author’s Accepted Manuscript, AAM (Post-print)
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/240979
Citazioni
  • Scopus 123
  • ???jsp.display-item.citation.isi??? 76
Social impact