The interest of the scientific community on the remote observation of sun-induced chlorophyll fluorescence (SIF) has increased in the recent years. In this context, hyperspectral ground measurements play a crucial role in the calibration and validation of future satellite missions. For this reason, the European cooperation in science and technology (COST) Action ES1309 OPTIMISE has compiled three papers on instrument characterization, measurement setups and protocols, and retrieval methods (current paper). This study is divided in two sections; first, we evaluated the uncertainties in SIF retrieval methods (e.g., Fraunhofer line depth (FLD) approaches and spectral fitting method (SFM)) for a combination of of-the-shelf commercial spectrometers. Secondly, we evaluated how an erroneous implementation of the retrieval methods increases the uncertainty in the estimated SIF values. Results show that the SFM approach applied to high-resolution spectra provided the most reliable SIF retrieval with a relative error (RE) ≤ 6% and < 5% for F 687 and F 760 , respectively. Furthermore, although the SFM was the least affected by an inaccurate definition of the absorption spectral window (RE = 5%) and/or interpolation strategy (RE = 15-30%), we observed a sensitivity of the SIF retrieval for the simulated training data underlying the SFM model implementation.
Cendrero-Mateo, M., Wieneke, S., Damm, A., Alonso, L., Pinto, F., Moreno, J., et al. (2019). Sun-induced chlorophyll fluorescence III: Benchmarking retrieval methods and sensor characteristics for proximal sensing. REMOTE SENSING, 11(8) [10.3390/rs11080921].
Sun-induced chlorophyll fluorescence III: Benchmarking retrieval methods and sensor characteristics for proximal sensing
Celesti M.;Rossini M.;Cogliati S.;
2019
Abstract
The interest of the scientific community on the remote observation of sun-induced chlorophyll fluorescence (SIF) has increased in the recent years. In this context, hyperspectral ground measurements play a crucial role in the calibration and validation of future satellite missions. For this reason, the European cooperation in science and technology (COST) Action ES1309 OPTIMISE has compiled three papers on instrument characterization, measurement setups and protocols, and retrieval methods (current paper). This study is divided in two sections; first, we evaluated the uncertainties in SIF retrieval methods (e.g., Fraunhofer line depth (FLD) approaches and spectral fitting method (SFM)) for a combination of of-the-shelf commercial spectrometers. Secondly, we evaluated how an erroneous implementation of the retrieval methods increases the uncertainty in the estimated SIF values. Results show that the SFM approach applied to high-resolution spectra provided the most reliable SIF retrieval with a relative error (RE) ≤ 6% and < 5% for F 687 and F 760 , respectively. Furthermore, although the SFM was the least affected by an inaccurate definition of the absorption spectral window (RE = 5%) and/or interpolation strategy (RE = 15-30%), we observed a sensitivity of the SIF retrieval for the simulated training data underlying the SFM model implementation.File | Dimensione | Formato | |
---|---|---|---|
10281-240768.pdf
accesso aperto
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Dimensione
15.45 MB
Formato
Adobe PDF
|
15.45 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.