The diagnosis of interstitial lung diseases in patients affected by rheumatoid arthritis is fundamental to improving their survival rate. In particular, the average survival time of patients affected by rheumatoid arthritis with pulmonary implications is approximately 3 years. The gold standard for confirming the diagnosis of this disease is computer tomography. However, it is very difficult to raise diagnosis suspicion because the symptoms of the disease are extremely common in elderly people. The detection of the so-called velcro crackle in lung sounds can effectively raise the suspicion of an interstitial disease and speed up diagnosis. However, this task largely relies on the experience of physicians and has not yet been standardized in clinical practice. The diagnosis of interstitial lung diseases based on thorax auscultation still represents an underexplored field in the study of rheumatoid arthritis. In this study, we investigate the problem of the automatic detection of velcro crackle in lung sounds. In practice, the patient is auscultated using a digital stethoscope and the lung sounds are saved to a file. The acquired digital data are then analysed using a suitably developed algorithm. In particular, the proposed solution relies on the empirical observation that the audio bandwidth associated with velcro crackle is larger than that associated with healthy breath sounds. Experimental results from a database of 70 patients affected by rheumatoid arthritis demonstrate that the developed tool can outperform specialized physicians in terms of diagnosing pulmonary disorders. The overall accuracy of the proposed solution is 90.0%, with negative and positive predictive values of 95.0% and 83.3%, respectively, whereas the reliability of physician diagnosis is in the range of 60−70%. The devised algorithm represents an enabling technology for a novel approach to the diagnosis of interstitial lung diseases in patients affected by rheumatoid arthritis.

Pancaldi, F., Sebastiani, M., Cassone, G., Luppi, F., Cerri, S., Della Casa, G., et al. (2018). Analysis of pulmonary sounds for the diagnosis of interstitial lung diseases secondary to rheumatoid arthritis. COMPUTERS IN BIOLOGY AND MEDICINE, 96, 91-97 [10.1016/j.compbiomed.2018.03.006].

Analysis of pulmonary sounds for the diagnosis of interstitial lung diseases secondary to rheumatoid arthritis

Luppi, Fabrizio;
2018

Abstract

The diagnosis of interstitial lung diseases in patients affected by rheumatoid arthritis is fundamental to improving their survival rate. In particular, the average survival time of patients affected by rheumatoid arthritis with pulmonary implications is approximately 3 years. The gold standard for confirming the diagnosis of this disease is computer tomography. However, it is very difficult to raise diagnosis suspicion because the symptoms of the disease are extremely common in elderly people. The detection of the so-called velcro crackle in lung sounds can effectively raise the suspicion of an interstitial disease and speed up diagnosis. However, this task largely relies on the experience of physicians and has not yet been standardized in clinical practice. The diagnosis of interstitial lung diseases based on thorax auscultation still represents an underexplored field in the study of rheumatoid arthritis. In this study, we investigate the problem of the automatic detection of velcro crackle in lung sounds. In practice, the patient is auscultated using a digital stethoscope and the lung sounds are saved to a file. The acquired digital data are then analysed using a suitably developed algorithm. In particular, the proposed solution relies on the empirical observation that the audio bandwidth associated with velcro crackle is larger than that associated with healthy breath sounds. Experimental results from a database of 70 patients affected by rheumatoid arthritis demonstrate that the developed tool can outperform specialized physicians in terms of diagnosing pulmonary disorders. The overall accuracy of the proposed solution is 90.0%, with negative and positive predictive values of 95.0% and 83.3%, respectively, whereas the reliability of physician diagnosis is in the range of 60−70%. The devised algorithm represents an enabling technology for a novel approach to the diagnosis of interstitial lung diseases in patients affected by rheumatoid arthritis.
Articolo in rivista - Articolo scientifico
Detection; Early diagnosis; Estimation; Interstitial lung disease; Lung sounds; Rheumatoid arthritis; Velcro crackle;
English
2018
96
91
97
none
Pancaldi, F., Sebastiani, M., Cassone, G., Luppi, F., Cerri, S., Della Casa, G., et al. (2018). Analysis of pulmonary sounds for the diagnosis of interstitial lung diseases secondary to rheumatoid arthritis. COMPUTERS IN BIOLOGY AND MEDICINE, 96, 91-97 [10.1016/j.compbiomed.2018.03.006].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/219295
Citazioni
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 25
Social impact