BACKGROUND: The wide diffusion of multicomponent collection in donor apheresis has led to the yielding of different components, such as plasma-reduced plateletpheresis at high PLT concentration. We investigated whether this collection modality could induce more PLT activation compared to standard plateletpheresis. STUDY DESIGN AND METHODS: Forty-one plateletpheresis collections (20 Trima and 21 Spectra LRS Turbo v.7.0, COBE) were evaluated. Donor, procedure, and product data were recorded. ADP, collagen, and U46619 (a thromboxane-A2 analog)-induced PLT aggregation was investigated in basal (donor) and final (plateletpheresis unit) samples. The expression of PLT activation marker P-selectin (CD62P) was studied using flow cytometry in basal and final samples. In all cases, P-selectin was investigated in final samples after stimulation with ADP to assess for a possible further release of the antigen. Four additional plateletpheresis procedures were performed in donors from Group A, using the traditional, nonplasma-reduced program. RESULTS: Plateletpheresis obtained by means of the Trima device showed a lower response to in-vitro induced PLT aggregation and a higher percentage of P-selectin-expressing PLT when compared to products obtained using the Spectra device. Moreover, P-selectin release after ADP stimulation was reduced in plateletpheresis units obtained using the Trima device. These differences disappeared when a nonplasma-reduced collection program was used. In-vivo evaluation did not detect any difference between platelepheresis obtained by means of the two cell separators. CONCLUSIONS: Plateletpheresis units obtained by means of multicomponent collection show a higher degree of PLT activation compared to traditional plateletpheresis procedures when high-concentration plasma-reduced products are collected. Randomized clinical studies are needed to assess the real impact of these findings in terms of in-vivo efficacy of plasma-reduced plateletpheresis units.

Perseghin, P., Mascaretti, L., Speranza, T., Belotti, D., Baldini, V., Dassi, M., et al. (2004). Platelet activation during plasma-reduced multicomponent PLT collection: A comparison between COBE Trima and Spectra LRS turbo cell separators. TRANSFUSION, 44(1), 125-130 [10.1046/j.0041-1132.2004.00613.x].

Platelet activation during plasma-reduced multicomponent PLT collection: A comparison between COBE Trima and Spectra LRS turbo cell separators

BELOTTI, DANIELA;POGLIANI, ENRICO MARIA;
2004

Abstract

BACKGROUND: The wide diffusion of multicomponent collection in donor apheresis has led to the yielding of different components, such as plasma-reduced plateletpheresis at high PLT concentration. We investigated whether this collection modality could induce more PLT activation compared to standard plateletpheresis. STUDY DESIGN AND METHODS: Forty-one plateletpheresis collections (20 Trima and 21 Spectra LRS Turbo v.7.0, COBE) were evaluated. Donor, procedure, and product data were recorded. ADP, collagen, and U46619 (a thromboxane-A2 analog)-induced PLT aggregation was investigated in basal (donor) and final (plateletpheresis unit) samples. The expression of PLT activation marker P-selectin (CD62P) was studied using flow cytometry in basal and final samples. In all cases, P-selectin was investigated in final samples after stimulation with ADP to assess for a possible further release of the antigen. Four additional plateletpheresis procedures were performed in donors from Group A, using the traditional, nonplasma-reduced program. RESULTS: Plateletpheresis obtained by means of the Trima device showed a lower response to in-vitro induced PLT aggregation and a higher percentage of P-selectin-expressing PLT when compared to products obtained using the Spectra device. Moreover, P-selectin release after ADP stimulation was reduced in plateletpheresis units obtained using the Trima device. These differences disappeared when a nonplasma-reduced collection program was used. In-vivo evaluation did not detect any difference between platelepheresis obtained by means of the two cell separators. CONCLUSIONS: Plateletpheresis units obtained by means of multicomponent collection show a higher degree of PLT activation compared to traditional plateletpheresis procedures when high-concentration plasma-reduced products are collected. Randomized clinical studies are needed to assess the real impact of these findings in terms of in-vivo efficacy of plasma-reduced plateletpheresis units.
Articolo in rivista - Articolo scientifico
Male; Adenosine Diphosphate; Blood Platelets; Middle Aged; Platelet Count; Female; Humans; Platelet Transfusion; P-Selectin; Platelet Activation; Plateletpheresis; Adult; Hematologic Diseases; Platelet Aggregation
English
2004
44
1
125
130
none
Perseghin, P., Mascaretti, L., Speranza, T., Belotti, D., Baldini, V., Dassi, M., et al. (2004). Platelet activation during plasma-reduced multicomponent PLT collection: A comparison between COBE Trima and Spectra LRS turbo cell separators. TRANSFUSION, 44(1), 125-130 [10.1046/j.0041-1132.2004.00613.x].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/20721
Citazioni
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 24
Social impact