The CaPiRe program has been started to develop a new detector design, in order to produce large areas of glass Resistive Plate Chambers (RPC) detectors, overcoming the previous limitations. As a first step we produced our glass RPC detectors (1 m(2)) at General Tecnica exploiting their standard procedures, materials and production techniques simply using 2 mm glass electrodes instead of the bakelite ones. A set of RPC was produced by using pre-coated (silk screen printed) electrodes, while others were produced with the standard graphite coating. All the detectors, together with four old Glass RPC acting as reference, were tested at the DAPhiNE Test Beam Facility with 500 MeV electrons in order to study the efficiency in different positions inside the detectors (i.e. near spacers and edges) and to study the detector behavior as a function of the local particle rate

Calcaterra, A., De Sangro, R., Gamba, D., Mannocchi, G., Patteri, P., Picchi, P., et al. (2004). Test of large area glass RPCs at the DAΦNE test beam facility (BTF). NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 533(1-2), 154-158 [10.1016/j.nima.2004.07.019].

Test of large area glass RPCs at the DAΦNE test beam facility (BTF)

RAGAZZI, STEFANO;TABARELLI DE FATIS, TOMMASO;
2004

Abstract

The CaPiRe program has been started to develop a new detector design, in order to produce large areas of glass Resistive Plate Chambers (RPC) detectors, overcoming the previous limitations. As a first step we produced our glass RPC detectors (1 m(2)) at General Tecnica exploiting their standard procedures, materials and production techniques simply using 2 mm glass electrodes instead of the bakelite ones. A set of RPC was produced by using pre-coated (silk screen printed) electrodes, while others were produced with the standard graphite coating. All the detectors, together with four old Glass RPC acting as reference, were tested at the DAPhiNE Test Beam Facility with 500 MeV electrons in order to study the efficiency in different positions inside the detectors (i.e. near spacers and edges) and to study the detector behavior as a function of the local particle rate
Articolo in rivista - Articolo scientifico
RPC; production; rate capability
English
1-nov-2004
533
1-2
154
158
none
Calcaterra, A., De Sangro, R., Gamba, D., Mannocchi, G., Patteri, P., Picchi, P., et al. (2004). Test of large area glass RPCs at the DAΦNE test beam facility (BTF). NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 533(1-2), 154-158 [10.1016/j.nima.2004.07.019].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/1994
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
Social impact